Glassware Washers and Dryers

Glassware Washers and Dryers
Filtered Search Results

Miele Professional™ Mobile Injector Unit E 355
Mobile unit E 355 for the optimum loading of narrow necked glassware
Miele Professional™ Powder Dispensing (AD)
Convenient drying support - EcoDry with AD water connection
Height (Metric) | 83.50 cm |
---|---|
Inlet Water Temperature (English) Recommended | 5°C to 65°C |
Depth (English) | 23 9/16 in. |
Width (English) | 23 9/16 in. |
Color | Lotus White |
Min. Purified Water Pressure | 200 kPa |
Inlet Water Temperature (Metric) Recommended | 5°C to 65°C |
Material | Stainless Steel |
Inlet Water Temperature (Metric) Max. | 65°C |
Inlet Water Temperature (English) Max. | 65°C |
For Use With (Application) | Cleaning of Laboratory Glassware |
Width (Metric) | 59.80 cm |
Max. Pressure | 1000 kPa |
Flow Rate | 500 L/min. |
Product Type | Laboratory Washer/Dryer |
Depth (Metric) | 59.80 cm |
Voltage | 400 V |
Frequency | 50 Hz |
Inlet Water Temperature (English) Min. | 5°C |
Inlet Water Temperature (Metric) Min. | 5°C |
Height (English) | 32 7/8 in. |
Display | Full-color Touch Screen |
Miele Professional™ Lab Washer with Pump for AD water
Efficient use of resources - variable speed heater pump with conductivity monitoring
Inlet Water Temperature (English) Recommended | 5°C to 65°C |
---|---|
Min. Purified Water Pressure | 200 kPa |
Inlet Water Temperature (Metric) Recommended | 5°C to 65°C |
Material | Stainless Steel |
Inlet Water Temperature (Metric) Max. | 65°C |
Inlet Water Temperature (English) Max. | 65°C |
For Use With (Application) | Cleaning of Laboratory Glassware |
Max. Pressure | 1000 kPa |
Flow Rate | 500 L/min. |
Product Type | Laboratory Washer/Dryer |
Frequency | 50 Hz |
Inlet Water Temperature (English) Min. | 5°C |
Inlet Water Temperature (Metric) Min. | 5°C |
Display | Full-color Touch Screen |
Miele Professional™ Dosing system
Dosing cabinet PG 8596 (AE) for the storage of process chemicals and dosing modules
Miele Professional SlimLine Lab Washer PLW 7111 S-1002
SlimLine lab washer with electric heating, hot air drying, drain pump, capacitor, water softener, oil-based app, and water protection.
Miele Professional SlimLine Lab Washer PLW 7111 S-1011
SlimLine lab washer with electric heating, hot air drying, drain pump, and capacitor.
Miele Professional™ Lab Washer with DI Water Connection
Excellent user convenience with touch display with DI water connection
Height (Metric) | 83.50 cm |
---|---|
Inlet Water Temperature (English) Recommended | 5°C to 65°C |
Depth (English) | 23 9/16 in. |
Width (English) | 23 9/16 in. |
Min. Purified Water Pressure | 200 kPa |
Inlet Water Temperature (Metric) Recommended | 5°C to 65°C |
Material | Stainless Steel |
Inlet Water Temperature (Metric) Max. | 65°C |
Inlet Water Temperature (English) Max. | 65°C |
For Use With (Application) | Cleaning of Laboratory Glassware |
Width (Metric) | 59.80 cm |
Max. Pressure | 1000 kPa |
Flow Rate | 500 L/min. |
Product Type | Laboratory Washer/Dryer |
Depth (Metric) | 59.80 cm |
Frequency | 50 Hz |
Inlet Water Temperature (English) Min. | 5°C |
Inlet Water Temperature (Metric) Min. | 5°C |
Height (English) | 32 7/8 in. |
Display | Touch Screen |
Miele Professional™ Feed Pump for DI Water
Final rinse with fully demineralised water with ease dispense process chemicals
Height (Metric) | 83.50 cm |
---|---|
Inlet Water Temperature (English) Recommended | 5°C to 65°C |
Depth (English) | 23 9/16 in. |
Width (English) | 23 9/16 in. |
Min. Purified Water Pressure | 200 kPa |
Inlet Water Temperature (Metric) Recommended | 5°C to 65°C |
Material | Stainless Steel |
Inlet Water Temperature (Metric) Max. | 65°C |
Inlet Water Temperature (English) Max. | 65°C |
For Use With (Application) | Cleaning of Laboratory Glassware |
Width (Metric) | 59.80 cm |
Max. Pressure | 1000 kPa |
Flow Rate | 500 L/min. |
Product Type | Laboratory Glassware Washer |
Depth (Metric) | 59.80 cm |
Frequency | 50 Hz |
Inlet Water Temperature (English) Min. | 5°C |
Inlet Water Temperature (Metric) Min. | 5°C |
Height (English) | 32 7/8 in. |
Display | Touch Screen |
Miele Professional™ Liquid Dispensing (AD)
Flexible and simple, modular load carriers and EasyLoad system with AD water connection
Height (Metric) | 83.50 cm |
---|---|
Inlet Water Temperature (English) Recommended | 5°C to 65°C |
Width (English) | 23 9/16 in. |
Color | Lotus White |
Min. Purified Water Pressure | 200 kPa |
Inlet Water Temperature (Metric) Recommended | 5°C to 65°C |
Material | Stainless Steel |
Inlet Water Temperature (Metric) Max. | 65°C |
Inlet Water Temperature (English) Max. | 65°C |
For Use With (Application) | Cleaning of Laboratory Glassware |
Width (Metric) | 59.80 cm |
Max. Pressure | 1000 kPa |
Flow Rate | 500 L/min. |
Frequency | 50 Hz |
Inlet Water Temperature (English) Min. | 5°C |
Inlet Water Temperature (Metric) Min. | 5°C |
Height (English) | 32 7/8 in. |
Display | Full-color Touch Screen |
Miele Professional™ Lab Washer with Drying unit DryPlus
With liquid dispensing and Efficient hot air drying - DryPlus
Inlet Water Temperature (English) Recommended | 5°C to 65°C |
---|---|
Min. Purified Water Pressure | 200 kPa |
Inlet Water Temperature (Metric) Recommended | 5°C to 65°C |
Material | Stainless Steel |
Inlet Water Temperature (Metric) Max. | 65°C |
Inlet Water Temperature (English) Max. | 65°C |
For Use With (Application) | Cleaning of Laboratory Glassware |
Max. Pressure | 1000 kPa |
Includes | DryPlus |
For Use With (Equipment) | Washer-Disinfectors |
Product Type | Laboratory Washer/Dryer |
Frequency | 50 Hz |
Inlet Water Temperature (English) Min. | 5°C |
Inlet Water Temperature (Metric) Min. | 5°C |
Display | Full-color Touch Screen |
Miele Professional™ Lab Washer Feed Pump for AD water
Convenient drying support - liquid dispensing and EcoDry function for AD water
Height (Metric) | 83.50 cm |
---|---|
Inlet Water Temperature (English) Recommended | 5°C to 65°C |
Depth (English) | 23 9/16 in. |
Width (English) | 23 9/16 in. |
Min. Purified Water Pressure | 200 kPa |
Inlet Water Temperature (Metric) Recommended | 5°C to 65°C |
Material | Stainless Steel |
Inlet Water Temperature (Metric) Max. | 65°C |
Inlet Water Temperature (English) Max. | 65°C |
Width (Metric) | 59.80 cm |
Max. Pressure | 1000 kPa |
Flow Rate | 500 L/min. |
Product Type | Laboratory Glassware Washer |
Depth (Metric) | 59.80 cm |
Frequency | 50 Hz |
Inlet Water Temperature (English) Min. | 5°C |
Inlet Water Temperature (Metric) Min. | 5°C |
Height (English) | 32 7/8 in. |
Display | Full-color Touch Screen |
Miele Professional SlimLine Lab Washer PLW 7111 S-1018
SlimLine lab washer with electric heating, hot air drying, drain pump, capacitor, water softener, conductivity meter, and oil-based app.
Miele Professional SlimLine Lab Washer PLW 7111 S-1001
SlimLine lab washer with electric heating, hot air drying, drain pump, capacitor, and water protection.
Miele Professional SlimLine Lab Washer PLW 7111 Safety B-1002
SlimLine lab washer with electric heating, drain pump, capacitor, and water softener.
Miele Professional™ Closed Plinth UC 30-90/70-78
Closed plinth UC 30-90/70-78 to raise the machine, 70 cm deep, 90 cm wide