Filtered Search Results
Invitrogen™ CyQUANT™ MTT and XTT Cell Viability Assays
CyQUANT MTT and XTT Cell Viability assays are colorimetric microplate assays for accurate assessment of cell health, proliferation, and cytotoxicity. CyQUANT MTT is a well-established assay, while CyQUANT XTT offers improved performance and continuous measurement without cell lysis or solubilization.
| Format | 96-well plate |
|---|---|
| Product Type | Cell Viability Assay |
| For Use With (Equipment) | Microplate Reader |
| For Use With (Application) | Viability Assay,Proliferation Assay,Cytotoxicity Assay |
| Product Line | CyQUANT |
| Detection Method | Colorimetric |
| Cell Type | Mammalian Cells |
Invitrogen™ MitoSOX™ Mitochondrial Superoxide Indicators, for live-cell imaging
MitoSOX superoxide indicators are novel fluorogenic dyes specifically targeted to mitochondria in live cells. Oxidation of the MitoSOX reagent by mitochondrial superoxide produces bright green or red fluorescence.
| Product Line | MitoSOX™ |
|---|---|
| Detection Method | Fluorescence |
Molecular Probes™ Annexin V Conjugates for Apoptosis Detection
Detect early stages of apoptosis with Annexin V stand-alone Alexa Fluor, APC, Pacific Blue, PE, FITC, and biotin conjugates using flow cytometry.
| Shipping Condition | Wet Ice |
|---|---|
| For Use With (Equipment) | Flow Cytometer |
| Product Type | Annexin V conjugate |
Invitrogen™ CM-H2DCFDA (General Oxidative Stress Indicator)
General oxidative stress indicator
Invitrogen™ CellEvent™ Senescence Green Detection Kit
CellEvent™ Senescence Green Detection Kit consists of a fluorescent probe and optimized buffer that enable the image-based detection of senescent cells
| Shipping Condition | Approved for shipment at Room Temperature or on Wet Ice |
|---|---|
| Format | 96-well plate |
| Product Type | Senescence Green Detection Kit |
| For Use With (Equipment) | Fluorescence Microscope,High Content Analysis Instrument |
| Product Line | CellEvent |
| Detection Method | Fluorescence |
| Cell Type | Mammalian Cells |
Invitrogen™ CyQUANT™ LDH and G6PD Cytotoxicity Assays
CyQUANT cytotoxicity assays measure cellular toxicity based on the release of cytosolic enzymes (LDH or G6PD) from damaged cells. These cytotoxicity assays utilize either colorimetric or fluorescence detection and allow continuous monitoring of cell death using microplate readers.
| Cell Permeability | Cell-impermeant |
|---|---|
| Format | 96-well plate |
| Product Type | LDH Cytotoxicity Assay |
| For Use With (Equipment) | Microplate Reader |
| Color | Red |
| Dye Type | Other Label(s) or Dye(s), Resorufin |
| Product Line | CyQUANT |
| Detection Method | Colorimetric, Fluorescence |
Molecular Probes™ Dead Cell Apoptosis Kits with Annexin V for Flow Cytometry
Assess cell viability with Dead Cell Apoptosis kits with Annexin V and conjugated fluorescent dyes such as Alexa Fluor 488, FITC, PI, PE, APC, and SYTOX Green.
| Shipping Condition | Wet Ice |
|---|---|
| Content And Storage | Store in refrigerator (2°C to 8°C) and protect from light. |
| Product Type | Apoptosis Detection Kit |
Invitrogen™ CellEvent™ Caspase-3/7 Detection Reagents
CellEvent Caspase-3/7 detection reagents are novel fluorogenic substrates for apoptosis detection. These substrates detect activated caspase-3/7 in live cells that can be fixed and multiplexed with antibody detection workflows.
| Detection Method | Fluorescence |
|---|
Invitrogen™ Dextran, Tetramethylrhodamine, 3000 MW, Anionic, Lysine Fixable
Rigorous methods for removing as much unconjugated dye as practical, followed by assay of dextran conjugates by thin-layer chromatography to help ensure absence of low molecular weight contaminants
Invitrogen™ Dextran, Alexa Fluor™ 555; 10,000 MW, Anionic, Fixable
Rigorous methods for removing as much unconjugated dye as practical, followed by assay of dextran conjugates by thin-layer chromatography to help ensure absence of low molecular weight contaminants
Invitrogen™ Annexin Binding Buffer (5X), for flow cytometry
Annexin Binding Buffer (5X), for flow cytometry
Invitrogen™ PrestoBlue™ and PrestoBlue™ HS Cell Viability Reagents
Monitor cell proliferation and viability with the resazurin-based PrestoBlue and PrestoBlue HS cell viability reagents. These nontoxic and cell permeable reagents quantitatively measure cell viability in as little as 10 minutes using absorbance- or fluorescence-based microplate readers.
| Content And Storage | Store at 2°C to 8°C and protect from light. |
|---|---|
| Form | Liquid |
| Product Type | Cell Viability Reagent |
| For Use With (Equipment) | Microplate Reader,Spectrophotometer,HTS Reader |
| For Use With (Application) | Viability Assay |
| Product Line | PrestoBlue |
| Detection Method | Colorimetric, Fluorescence |
Invitrogen™ Dextran, Cascade Blue™, 10,000 MW, Anionic, Lysine Fixable
Rigorous methods for removing as much unconjugated dye as practical, followed by an assay of dextran conjugates by thin-layer chromatography to help ensure the absence of low molecular weight contaminants
Molecular Probes™ CellEvent™ Caspase-3/7 Green Flow Cytometry Assay Kit
The CellEvent™ Caspase-3/7 Green Flow Cytometry Assay Kit enables the flow cytometric detection of activated caspase-3 and caspase-7 in apoptotic cells.
| Shipping Condition | Wet Ice |
|---|---|
| Content And Storage | Contains 1 vial CellEvent™ Caspase 3/7 Green Detection Reagent, 1 vial SYTOX AADvanced dead cell stain, and 1 vial of DMSO. Store all vials in the kit upright, at or below -20deg;C, desiccated, and protected from light. |
| Format | Kit |
| For Use With (Equipment) | Attune™ Acoustic Focusing Cytometer, Flow Cytometer |
| Flow Cytometer Laser Lines | 488 |
| Product Type | Caspase Assay Kit |
| Label or Dye | CellEvent™ Caspase 3/7 Green Detection Reagent, SYTOX AADvanced dead cell stain |
| Label Type | Other Label(s) or Dye(s) |
| For Use With (Application) | Flow Cytometry |
| Detection Method | Fluorescence |
| Product Line | CellEvent™ |