Cell Function Reagents and Kits
- (1)
- (1)
- (1)
- (1)
- (1)
- (5)
- (1)
- (1)
- (1)
- (4)
- (12)
- (4)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (3)
- (2)
- (1)
- (1)
- (6)
- (1)
- (2)
- (1)
- (1)
- (1)
- (3)
- (1)
- (3)
- (1)
- (1)
- (27)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (2)
- (2)
- (2)
- (7)
- (16)
- (2)
- (2)
- (1)
- (8)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (6)
- (1)
- (1)
- (4)
- (5)
- (2)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (32)
- (70)
- (4)
- (1)
- (15)
- (1)
- (14)
- (1)
- (1)
- (3)
- (1)
- (1)
- (1)
- (1)
- (1)
- (3)
- (1)
- (1)
- (1)
- (1)
- (9)
- (1)
- (1)
- (1)
- (1)
- (4)
- (1)
- (5)
- (1)
- (1)
- (1)
- (1)
- (1)
- (4)
- (1)
- (1)
- (1)
- (1)
- (5)
- (3)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (3)
- (3)
- (1)
- (1)
- (2)
- (2)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (10)
- (1)
- (3)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (2)
- (4)
- (1)
- (40)
- (1)
- (12)
- (1)
- (1)
- (12)
- (1)
- (1)
- (1)
- (1)
- (2)
- (3)
- (1)
- (9)
- (3)
- (6)
- (2)
- (2)
- (35)
- (1)
- (9)
- (160)
- (9)
- (211)
- (24)
- (24)
- (31)
- (68)
- (6)
- (2)
- (11)
- (112)
- (3)
- (1)
- (21)
- (1)
- (1)
- (16)
- (6)
- (7)
- (10)
- (18)
- (1)
- (4)
- (3)
- (1)
- (6)
- (2)
- (3)
- (5)
- (1)
- (4)
- (1)
- (12)
- (1)
- (10)
- (1)
- (2)
- (16)
- (3)
- (2)
- (1)
- (16)
- (1)
- (1)
- (1)
- (1)
- (3)
- (3)
- (7)
- (1)
- (1)
- (2)
- (1)
- (2)
- (3)
- (5)
- (1)
- (1)
- (31)
- (3)
- (1)
- (1)
- (1)
- (2)
- (1)
- (8)
- (4)
- (2)
- (2)
- (12)
- (2)
- (1)
- (2)
- (2)
- (1)
- (1)
- (1)
- (1)
- (2)
- (7)
- (2)
- (3)
- (2)
- (7)
- (3)
- (4)
- (1)
- (1)
- (1)
- (1)
- (3)
- (8)
- (5)
- (2)
- (1)
- (1)
- (4)
- (4)
- (2)
- (16)
- (2)
- (3)
- (1)
- (8)
- (2)
- (1)
- (8)
- (1)
- (1)
- (1)
- (1)
- (1)
- (18)
- (5)
- (1)
- (3)
- (1)
- (3)
- (2)
- (7)
- (7)
- (9)
- (1)
- (42)
- (5)
- (3)
- (1)
- (1)
- (2)
- (1)
- (1)
- (17)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (13)
- (1)
- (4)
- (3)
- (4)
- (1)
- (2)
- (5)
- (4)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (2)
- (1)
- (1)
- (1)
- (4)
- (2)
- (5)
- (1)
- (5)
- (24)
- (7)
- (2)
- (1)
- (1)
- (2)
- (1)
- (1)
- (3)
- (1)
- (1)
- (1)
- (1)
- (74)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (2)
- (2)
- (1)
- (1)
- (2)
- (1)
- (2)
- (2)
- (1)
- (1)
- (1)
- (1)
- (3)
- (1)
- (1)
- (3)
- (1)
- (1)
- (1)
- (1)
- (12)
- (2)
- (1)
- (2)
- (3)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (2)
- (4)
- (1)
- (3)
- (1)
- (2)
- (1)
- (3)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (5)
- (1)
- (1)
- (1)
- (7)
- (2)
- (2)
- (3)
- (2)
- (4)
- (2)
- (2)
- (1)
- (1)
- (2)
- (3)
- (1)
- (3)
- (3)
- (1)
- (2)
- (3)
- (3)
- (1)
- (1)
- (1)
- (1)
- (1)
- (25)
- (5)
Filtered Search Results
Invitrogen™ LIVE/DEAD™ Viability/Cytotoxicity Kit, for mammalian cells
Useful with a variety of fluorescence-detection methodologies
Invitrogen™ CellTrace™ CFSE Cell Proliferation Kit, for flow cytometry
CellTrace™ CFSE Cell Proliferation Kit is used for in vitro and in vivo labeling of cells to trace multiple generations using dye dilution by flow cytometry.
| Shipping Condition | Room Temperature |
|---|---|
| Format | Tube(s) |
| Product Type | Cell Proliferation Kit |
| For Use With (Equipment) | Flow Cytometer |
| Emission | 488 |
| Product Line | CellTrace |
| Detection Method | Fluorescence |
Molecular Probes™ LIVE/DEAD™ Fixable Aqua Dead Cell Stain Kit, for 405 nm excitation
The LIVE/DEAD™ Fixable Aqua Dead Cell Stain Kit is used to determine the viability of cells prior to the fixation and permeabilization required for intracellular antibody staining, or prior to elimination of biohazardous materials using formaldehyde fixation.
| Shipping Condition | Room Temperature |
|---|---|
| dimExcitationWavelengthRange | 375 nm |
| Description | LIVE/DEAD™ Fixable Aqua Dead Cell Stain Kit, for 405 nm excitation |
| Form | Solid |
| Color | Aqua |
| Emission | 526 |
| Dye Type | LIVE/DEAD™ Fixable Aqua Dead Cell Stain |
| For Use With (Application) | Viability Assay |
| Detection Method | Fluorescence |
| Cell Type | Eukaryotic Cells |
| Cell Permeability | Impermeant |
| Product Type | Stain |
| For Use With (Equipment) | Flow Cytometer |
| Product Line | LIVE/DEAD |
Molecular Probes™ LIVE/DEAD™ BacLight™ Bacterial Viability Kits
LIVE/DEAD™ BacLight™ Bacterial Viability Kits are easy-to-use fluorescent staining kits commonly used for assessing the viability of bacterial cells. These kits provide a two-color fluorescence assay of bacterial viability using green and red fluorescent dyes for use with imaging, flow, and assays.
| Shipping Condition | Room Temperature |
|---|---|
| Product Type | Bacterial Viability Kit |
| Dye Type | Other Label(s) or Dye(s) |
| Product Line | BacLight, LIVE/DEAD |
| Detection Method | Fluorescence |
| Cell Type | Bacteria |
Invitrogen™ CyQUANT™ MTT and XTT Cell Viability Assays
CyQUANT MTT and XTT Cell Viability assays are colorimetric microplate assays for accurate assessment of cell health, proliferation, and cytotoxicity. CyQUANT MTT is a well-established assay, while CyQUANT XTT offers improved performance and continuous measurement without cell lysis or solubilization.
| Format | 96-well plate |
|---|---|
| Product Type | Cell Viability Assay |
| For Use With (Equipment) | Microplate Reader |
| For Use With (Application) | Viability Assay,Proliferation Assay,Cytotoxicity Assay |
| Product Line | CyQUANT |
| Detection Method | Colorimetric |
| Cell Type | Mammalian Cells |
Invitrogen™ CyQUANT™ Cell Proliferation Assays
CyQUANT cell proliferation assays are fast and highly sensitive fluorescence methods for counting cells to assess cell growth and cytotoxicity in microplate format. These assays use fluorescent nucleic-acid-binding dyes to measure cell number based on DNA content.
| For Use With (Application) | Proliferation Assay |
|---|---|
| Product Line | CyQUANT |
Invitrogen™ Amplex™ Red and Amplex™ UltraRed Reagents
The Amplex Red and UltraRed reagents are fluorogenic substrates for peroxidase. These highly sensitive and stable probes react with H2O2 in the presence of HRP for solution-based assays and ELISAs. Amplex UltraRed is a brighter version of Amplex Red with an improved pH range and sensitivity.
| Substrate | HRP (Horseradish Peroxidase) Substrate |
|---|---|
| Shipping Condition | Room Temperature |
| Content And Storage | Store in freezer (-5°C to -30°C). |
| Form | Solid |
| Product Type | Red Hydrogen Peroxide |
| For Use With (Equipment) | Fluorometer,Microplate Reader |
| Validated Application | Cell Analysis |
| For Use With (Application) | Hydrogen Peroxidase Assay |
| Product Line | Amplex |
| Detection Method | Fluorescence |
Molecular Probes™ LIVE/DEAD™ Fixable Violet Dead Cell Stain Kit, for 405 nm excitation
The LIVE/DEAD™ Fixable Violet Dead Cell Stain Kit is used to determine the viability of cells prior to the fixation and permeabilization required for intracellular antibody staining, or prior to elimination of biohazardous materials using formaldehyde fixation.
| Shipping Condition | Room Temperature |
|---|---|
| dimExcitationWavelengthRange | 416 nm |
| Description | LIVE/DEAD™ Fixable Violet Dead Cell Stain Kit, for 405 nm excitation |
| Form | Solid |
| Solubility | DMSO (Dimethylsulfoxide) |
| Color | Violet |
| Emission | 451 |
| Dye Type | LIVE/DEAD™ Fixable Violet Dead Cell Stain |
| For Use With (Application) | Viability Assay |
| Detection Method | Fluorescence |
| Cell Type | Eukaryotic Cells |
| Cell Permeability | Impermeant |
| Format | Tube(s) |
| Product Type | Stain |
| For Use With (Equipment) | Flow Cytometer |
| Product Line | LIVE/DEAD |
Invitrogen™ pHrodo™ Red and Green Dextran, 10,000 MW, for Endocytosis
Perform fast and accurate live-cell endocytosis and imaging assays with pHrodo Red and Green dextran conjugates, which offer pH-sensitive pHrodo dyes that have no need for washing steps or quencher dye, and which can be multiplexed in imaging, HTS, HCA, tracing, and flow applications.
| Shipping Condition | Room Temperature |
|---|---|
| Content And Storage | Store at –20°C, desiccate, and protect from light. |
| Product Type | Supplement |
| Quantity | 0.5 mg |
| For Use With (Application) | Cell Analysis |
| Product Line | pHrodo |
| Detection Method | Fluorescence |
Thermo Scientific™ DRAQ5™ Fluorescent Probe Solution (5 mM)
Stain live or fixed cells with this far-red DNA stain.
| dimExcitationWavelengthRange | 647 nm |
|---|---|
| Content And Storage | Store at 4°C. |
| Purity or Quality Grade | > 99% |
| Form | Liquid |
| Solubility | Soluble at working concentrations in water and typical buffers |
| Color | Red |
| Emission | 681 |
| Dye Type | Cell-Permeant |
| For Use With (Application) | Cell Imaging |
| Detection Method | Fluorescence |
| Cell Permeability | Cell-permeant |
| Sub Cellular Localization | Nucleus, Cytosol, Cytoplasm |
| Product Type | Fluorescent Probe Solution |
| For Use With (Equipment) | Fluorescence Microscope,High Content Analysis Instrument |
| Product Line | Pierce |
Invitrogen™ 5(6)-CFDA (5-(and-6)-Carboxyfluorescein Diacetate), mixed isomers
A cell-permeant esterase substrate that can serve as a viability probe
| Shipping Condition | Room Temperature |
|---|---|
| Content And Storage | Store in freezer -5°C to -30°C and protect from light. |
| Product Type | Calcium Indicator |
| For Use With (Equipment) | Fluorescence Microscope |
| Dye Type | Fluorescent Dye-Based |
| For Use With (Application) | Cell Viability, Proliferation and Cellular Imaging |
| Detection Method | Fluorescence |
Invitrogen™ Click-iT™ EdU Cell Proliferation Kit for Imaging, Alexa Fluor™ 488 dye
Greener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
Optimized for fluorescence microscopy applications
Invitrogen™ Calcein AM, Cell-permeant Green and Blue Dyes
Calcein AM is a cell-permeant dye that can be used to determine cell viability in most eukaryotic cells. In live cells, the non-fluorescent Calcein AM is converted to green or blue fluorescent Calcein, after acetoxymethyl ester hydrolysis by intracellular esterases.
| Shipping Condition | Room Temperature |
|---|---|
| Content And Storage | Store in freezer (-5°C to -30°C) and protect from light. |
| For Use With (Equipment) | Fluorescence Microscope |
| Reagent Type | Cell Tracker Compounds, Cell Labeling Reagents |
| Dye Type | Other Label(s) or Dye(s) |
| For Use With (Application) | Cell Tracing,Cell Tracker |