missing translation for 'onlineSavingsMsg'
Learn More
Learn More
Description
No filtration or centrifugation of different crude samples necessary for antibody purification.
- Protein G Sepharose™ High Performance in prepacked spin columns
- Binds >1mg human IgG/column
- No filtration or centrifugation of different crude samples necessary for antibody purification
- Classic and crosslink protocols for protein enrichment (immunoprecipitation)
- Elution conditions formatted for both LC-MS and electrophoresis analysis
- Binding capacity >1mg IgG/column (determined with human polyclonal IgG)
- Stable in all commonly used buffers within antibody purification
- Contains polypropylene barrel and polyethylene frits
- Average particle size: 34μm
- Bed volume: 100μL
- Maximum sample volume: 600μL
- Short term (2h) pH stability: 2–9
- 600μL undiluted serum sample
Specifications
Specifications
| Bed Volume | 100 mL |
| Binding Capacity | > 1 mg IgG/column |
| Capacity (Metric) | 600 μL |
| Description | Ab SpinTrap columns are prepacked, single-use spin columns for rapid purification of monoclonal and polyclonal antibodies from serum and cell culture supernatants. Designed for small-scale purification of multiple samples in parallel. |
| Support Type | 6% Highly Cross-linked Agarose |
| Content And Storage | 4 to 8°C, 20% Ethanol |
| Quantity | 50 x 100 μL |
| For Use With (Application) | Centrifugation |
| Type | Spin Column |
| Sample Volume | 600 μl |
Safety and Handling
Product Identifier
- Ab SpinTrap, 50 columns
- Warning
- Flammable liquid Category 3
- H226-Flammable liquid and vapour.
- P280-Wear protective gloves/protective clothing/eye protection/face protection.
- P210-Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
- P303+P361+P353-IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/ shower.
- P501b-Dispose of contents/container in accordance with local/regional/national/international regulations.
- P243-Take precautionary measures against static discharge.
- MIXTURE LIST-Contains : ethanol
- UNKNOWN ACUTE-16.5 per cent of the mixture consists of component(s) of unknown acute toxicity.
Product Title
By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.
Spot an opportunity for improvement?