HPLC Columns
- (1)
- (9)
- (286)
- (622)
- (1)
- (178)
- (3)
- (922)
- (1)
- (64)
- (31)
- (8)
- (831)
- (182)
- (46)
- (6)
- (5)
- (1)
- (5)
- (14)
- (656)
- (12)
- (2)
- (1)
- (30)
- (6)
- (17)
- (12)
- (23)
- (71)
- (97)
- (346)
- (41)
- (8)
- (8)
- (4)
- (39)
- (39)
- (17)
- (197)
- (10)
- (53)
- (1)
- (864)
- (2)
- (2)
- (62)
- (2)
- (1,907)
- (12)
- (2)
- (64)
- (3)
- (23)
- (6)
- (6)
- (17)
- (6)
- (29)
- (8)
- (1)
- (2)
- (5)
- (14)
- (5)
- (4)
- (3)
- (10)
- (100)
- (2)
- (1)
- (237)
- (1)
- (2)
- (3)
- (201)
- (708)
- (1)
- (1)
- (146)
- (1)
- (2)
- (31)
- (9)
- (83)
- (471)
- (2)
- (4)
- (1)
- (106)
- (2)
- (408)
- (28)
- (1,081)
- (2)
- (2)
- (92)
- (2)
- (2)
- (11)
- (1)
- (20)
- (36)
- (1)
- (21)
- (14)
- (1)
- (1)
- (866)
- (2)
- (2)
- (6)
- (66)
- (1)
- (420)
- (1)
- (524)
- (212)
- (224)
- (116)
- (13)
- (601)
- (5)
- (68)
- (16)
- (5)
- (8)
- (54)
- (88)
- (180)
- (2)
- (14)
- (4)
- (6)
- (16)
- (198)
- (1)
- (16)
- (10)
- (3)
- (14)
- (104)
- (6)
- (2)
- (11)
- (2)
- (1)
- (9)
- (46)
- (1)
- (135)
- (35)
- (12)
- (1)
- (1)
- (191)
- (2)
- (1)
- (2)
- (13)
- (195)
- (60)
- (1)
- (11)
- (129)
- (2)
- (8)
- (2,605)
- (11)
- (21)
- (13)
- (10)
- (8)
- (3)
- (106)
- (9)
- (47)
- (13)
- (5)
- (4)
- (4)
Filtered Search Results
Thermo Scientific™ Hypersil™ BDS C18 Columns
Use as a robust, general-purpose column for a wide range of applications in QC/QA labs.
| Carbon Load | 11% |
|---|---|
| Stationary Phase | C18 |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| Surface Area | 170 m²/g |
| USP Type | L1 |
Thermo Scientific™ Acclaim™ 120 C18 Columns
Use these high-efficiency reversed phase C18 columns for maximum resolution in a wide variety of applications.
| Pore Size | 120 Å |
|---|---|
| Carbon Load | 18% |
| Stationary Phase | C18 |
| Temperature | 60°C |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| Surface Area | 300 m²/g |
| USP Type | L1 |
Thermo Scientific™ PepMap™ Neo Trap Cartridge
Use the Thermo Scientific™ PepMap™ Neo Trap Cartridge with PepMap™ Neo UHPLC Columns to filter impurities from your peptide mapping samples.
Thermo Scientific™ Hypersil™ ODS C18 Columns
Use as a general purpose C18 phase for acidic and neutral analytes.
| Pore Size | 120 Å |
|---|---|
| Carbon Load | 10% |
| Stationary Phase | C18 |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| Surface Area | 170 m²/g |
| USP Type | L1 |
Thermo Scientific™ EASY-Spray™ HPLC Columns
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Robust capillary flow HPLC columns for sensitive protein, peptide and mAbs separation using the stand alone or integrated easy to use design.
| Phase | Reversed Phase |
|---|
Thermo Scientific™ Hypersil GOLD™ C18 Selectivity HPLC Columns
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Use these endcapped, ultrapure, silica-based columns to generate exceptional peak shape and resolution for HPLC and LC/MS analyses using generic gradients
Thermo Scientific™ Hypersil™ APS-2 HPLC Columns, 5μm Particle Size
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Analyze sugars with this versatile amino propyl phase of Thermo ScientificTM HypersilTM APS-2 HPLC Columns.
| Pore Size | 120 Å |
|---|---|
| Carbon Load | 1.9% |
| Stationary Phase | Amino (NH2) |
| Temperature | 60°C |
| Phase | Reversed Phase, Normal Phase, Ion Exchange, HILIC |
| Endcapped | No |
| Packing Material | Spherical, Fully Porous Type A Silica |
| Column Type | Carbohydrate Analysis |
| pH | 2.5 to 8 |
| Surface Area | 170 m²/g |
| USP Type | L8 |
Thermo Scientific™ Hypercarb™ Porous Graphitic Carbon HPLC Columns
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Use for enhanced retention of polar compounds and separation of structurally related analytes with stability at pH extremes and high temperature.
Thermo Scientific™ POROS™ G 20 μm Protein G Affinty HPLC Columns
Thermo Scientific™ POROS™ Protein G is based on an immobilized recombinant Protein G functional group designed for high throughput purification of antibodies.
| Particle Size | 20 μm |
|---|---|
| Stationary Phase | Recombinant Protein G |
| Binding Capacity | 9 mg/mL |
| Column Type | Affinity |
| Material | PEEK |
| Product Line | POROS |
Thermo Scientific™ Acclaim™ PepMap™ 100 C18 HPLC Columns
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Use for high-resolution tryptic, natural, and synthetic peptide analyses. Its high loading capacity is exceptional for low abundant peptides in complex proteomic samples.
| Pore Size | 100 Å |
|---|---|
| Stationary Phase | C18 |
| Phase | Reversed Phase |
| USP Type | L1 |
Thermo Scientific™ Syncronis™ HILIC HPLC Columns
Maximize liquid chromatography reproducibility and laboratory productivity using Thermo Scientific™ Syncronis™ HILIC LC Columns.
| Pore Size | 100 Å |
|---|---|
| Carbon Load | 5% |
| Stationary Phase | Zwitterionic |
| Temperature | 60°C |
| Column Type | HILIC |
| pH | 2 to 8 |
| Surface Area | 320 m²/g |
Thermo Scientific™ EASY-Spray™ PepMap™ Neo UHPLC Columns
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Separate challenging peptide mapping samples with Thermo Scientific™ EASY-Spray™ PepMap™ Neo UHPLC columns.
| Pore Size | 100 Å |
|---|---|
| Stationary Phase | C18 |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| For Use With (Application) | Bottom-up Proteomics, LC-MS |
| Surface Area | 450 m2/g |
| Max. Pressure | 22,000 psi (1500 bar) |
| Column Format | Analytical Column, EASY-Spray™ |
| Particle Size | 2 μm |
| Carbon Load | 15% |
| Packing Material | Spherical, Fully Porous, Ultrapure Silica |
| Diameter (Metric) | 75 μm |
| pH | 2 to 8 |
| Product Line | Easy Spray |
| USP Type | L1 |
Thermo Scientific™ POROS™ CaptureSelect™ CH1-XL Affinity HPLC Columns
Thermo Scientific™ POROS™ CaptureSelect™ CH1-XL Affinity HPLC columns incorporate the advantages of high-speed POROS chromatography resins with the unique selectivity of CaptureSelect affinity ligands.
| Shipping Condition | Wet Ice |
|---|---|
| Pore Size | 2000 Å |
| Content And Storage | Column includes EZ grip fittings and column test certificate. Store at 2°C to 8°C. DO NOT FREEZE. |
| Stationary Phase | IgG Fab affinity ligand, CH1 domain of human IgG antibodies |
| Temperature | 2-40°C |
| Column Type | Affinity |
| Quantity | 1 Column |
| Material | PEEK |
| Max. Pressure | 2400 psi (170 bar) |
| Column Format | Analytical Column, Biocompatible PEEK |
| Particle Size | 20 μm |
| Packing Material | Highly Crosslinked Styrene-Divinylbenzene polymer (ST-DVB) |
| Binding Capacity | 26.2 mg/ml human IgG 8.8 mg/ml human Fab fragment |
| pH | 1-10 |
| Technique | Bio-LC |
| Product Line | POROS CaptureSelect |
Thermo Scientific™ Accucore™ C18 HPLC Columns
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Use this column, with its specially designed solid core, for a broad range of nonpolar analytes across multiple applications.
| Pore Size | 80 Å |
|---|---|
| Particle Size | 2.6 μm |
| Carbon Load | 9% |
| Stationary Phase | C18 |
| Temperature | 70°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| pH | 1 to 11 |
| Surface Area | 130 m²/g |
| Particle Shape | Solid Core |
| USP Type | L1 |
Thermo Scientific™ Aquasil™ 5μm C18 HPLC Columns, 5?m Particle Size
Thermo ScientificTM AquasilTM 5μm C18 HPLC Columns are available in limited dimensions. Please contact Customer Service for more details.
| Pore Size | 100 Å |
|---|---|
| Particle Size | 5 μm |
| Carbon Load | 12% |
| Stationary Phase | C18 |
| Phase | Reversed Phase |
| For Use With | LC/MS |
| Endcapped | Yes |
| Packing Material | Silica |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| Surface Area | 310 m²/g |
| USP Type | L1 |
| Column Format | Analytical Column |