GC Capillary Columns
- (3)
- (109)
- (6)
- (6)
- (26)
- (1)
- (1)
- (1)
- (188)
- (1)
- (2)
- (25)
- (190)
- (508)
- (6)
- (7)
- (5)
- (132)
- (4)
- (252)
- (2)
- (1)
- (4)
- (1)
- (2)
- (2)
- (40)
- (13)
- (21)
- (49)
- (36)
- (461)
- (510)
- (1)
- (2)
- (300)
- (1)
- (1)
- (100)
- (2)
- (1)
- (20)
- (11)
- (32)
- (438)
- (4)
- (3)
- (4)
- (45)
- (3)
- (259)
- (1)
- (1)
- (1)
- (1)
- (251)
- (1)
- (1)
- (1)
- (19)
- (29)
- (26)
- (14)
- (14)
- (4)
- (8)
- (51)
- (1)
- (2)
- (36)
- (3)
- (34)
- (7)
- (5)
- (7)
- (28)
- (9)
- (3)
- (7)
- (4)
- (2)
- (1)
- (3)
- (4)
- (7)
- (1)
- (2)
- (3)
- (2)
- (2)
- (2)
- (2)
- (2)
- (2)
- (2)
- (3)
- (2)
- (79)
- (8)
- (11)
- (4)
- (11)
- (36)
- (2)
- (37)
- (16)
- (10)
- (13)
- (3)
- (78)
- (9)
- (8)
- (17)
- (16)
- (11)
- (2)
- (1)
- (1)
- (14)
- (1)
- (15)
- (2)
- (14)
- (12)
- (27)
- (2)
- (27)
- (1)
- (4)
- (3)
- (2)
- (2)
- (17)
- (1)
- (1)
- (3)
- (26)
- (2)
- (2)
- (1)
- (4)
- (2)
- (2)
- (2)
- (1)
- (1)
- (2)
- (1)
- (3)
- (1)
- (19)
- (1)
- (1)
- (1)
- (1)
- (9)
- (1)
- (6)
- (6)
- (3)
- (7)
- (3)
- (17)
- (4)
- (24)
- (4)
- (3)
- (1)
- (1)
- (1)
- (1)
- (2)
- (4)
- (3)
- (2)
- (13)
- (10)
- (1)
- (2)
- (7)
- (17)
- (1)
- (3)
- (37)
- (8)
- (36)
- (21)
- (33)
- (1)
- (7)
- (21)
- (18)
- (9)
- (9)
- (37)
- (11)
- (8)
- (5)
- (18)
- (10)
- (9)
- (1)
- (2)
- (8)
- (6)
- (3)
- (3)
- (1)
- (8)
- (8)
- (10)
- (38)
- (24)
- (14)
- (14)
- (1)
- (8)
- (4)
- (5)
- (4)
- (4)
- (4)
- (273)
- (64)
- (60)
- (17)
- (46)
- (72)
- (77)
- (155)
- (28)
- (5)
- (7)
- (3)
- (2)
- (9)
- (35)
- (102)
- (83)
- (13)
- (7)
- (21)
- (8)
- (2)
Filtered Search Results
Thermo Scientific™ TraceGOLD™ TG-5MS GC Columns
Employ the most widely used MS phase in gas chromatography with the 5% phenyl phase Thermo Scientific™ TraceGOLD™ TG-5MS GC Column.
| USP Type | G27, G36 |
|---|
SGE™ BP20 (Wax) GC Capillary Columns
Combines innovative phase technology and unique fused silica production capability. SGE™ BP20 (Wax) GC Capillary Columns provides end-to-end separation solutions for all applications.
| Stationary Phase | SGE™ BP20 (Wax) |
|---|---|
| Polarity | Polar |
| Coating | Fused Silica |
| Functionality/Interaction Type | Hydrogen Bonding or Dipole interactions |
| USP Type | G14, G15, G16, G20, G39 |
Thermo Scientific™ TraceGOLD™ TG-624 and TG-624SilMS GC Columns
Optimize volatile organics analysis with this low-bleed, midpolarity GC column with high thermal stability.
| Polarity | Mid-Polar |
|---|---|
| USP Type | G43 |
Thermo Scientific™ TraceGOLD TG-5SilMS GC Columns
Incorporates phenyl groups in the polymer backbone for improved thermal stability, reduced bleed and reduced susceptibility to oxidation.
| Max. Temperature | 330/350°C |
|---|---|
| Stationary Phase | TraceGOLD™ TG-5 SilMS |
| Polarity | Low-Polar |
| For Use With (Application) | GC/MS Applications Using Ion-Trap Systems,GC/MS for Polycyclic Aromatics, Phthalates, Phenols, Amines, and Organophosphates,GC/MS for Hydrocarbons Including Chlorinated Hydrocarbons |
| USP Type | G27, G36 |
Thermo Scientific™ TraceGOLD TG-XLBMS GC Columns
Thermo Scientific™ TraceGOLD TG-XLBMS GC Columns offer a low polarity, low bleed column suitable for a wide range of applications.
| Max. Temperature | 340/360°C |
|---|---|
| Stationary Phase | TraceGOLD™ TG-XLBMS |
| Polarity | Low-Polar |
Thermo Scientific™ TraceGOLD™ TG-624SilMS GC Columns, 1.4μm film thickness, 0.53mm I.D., 30m length
Optimize volatile organics analysis with this low-bleed, midpolarity GC column with high thermal stability.
Thermo Scientific™ TRACE™ TR-1 GC Column
Use this non-polar GC column for method development and analysis of chlorinated and nitroaromatic compounds and environmental samples.
Thermo Scientific™ TraceGOLD™ TG-ALC Plus II GC Columns
Perform fast, full separation of blood alcohols and other volatile compounds by headspace gas chromatography using Thermo Scientific™ TraceGOLD™ TG-ALC GC columns.
| Max. Temperature | 260°C |
|---|---|
| Product Line | TraceGOLD |
Thermo Scientific™ TraceGOLD™ TG-624SilMS GC Columns, 1.4μm film thickness, 0.25mm I.D., 30m length
Optimize volatile organics analysis with this low-bleed, midpolarity GC column with high thermal stability.
Thermo Scientific™ TraceGOLD TG-1301MS GC Columns
Provides low-bleed, excellent reproducibility and column-to-column consistency even with sensitive detectors like ECDs and MS.
| Max. Temperature | 260/280°C |
|---|---|
| Stationary Phase | TraceGOLD™ TG-1301 MS |
| Polarity | Mid-Polar |
| USP Type | G43 |
Thermo Scientific™ TraceGOLD™ TG-WaxMS B GC Columns
Identify basic analytes with high performance, sensitivity, and reproducibility without derivatization or column priming.
| Max. Temperature | 200/220°C |
|---|---|
| Stationary Phase | TraceGOLD™ TG-WAXMS B |
| Polarity | Polar |
Thermo Scientific™ TRACE™ TR-BioDiesel GC Columns
Determine methanol, fatty acid methyl esters (FAMEs) and glycerides in biodiesel analysis with high performance and reproducibility.
| Max. Temperature | 300/320°C |
|---|---|
| Stationary Phase | Trace™ TR-BioDiesel |
| USP Type | G1, G2, G38 |
| Product Line | TRACE |
Thermo Scientific™ TraceGOLD TG-POLAR GC Columns
Redefine your expectations for high-polarity GC columns with the Thermo Scientific TraceGold TG-POLAR Columns
| Max. Temperature | 260/275°C |
|---|---|
| Stationary Phase | TraceGOLD™ TG-Polar |
| Polarity | Highly Polar |
| USP Type | G8, G48 |
Thermo Scientific™ TracePLOT™ TG-BOND Msieve 5A GC Columns
Designed for separation of Ar/O2 and other permanent gases
Thermo Scientific™ TraceGOLD TG-5HT GC Columns
Thermo Scientific™ TraceGOLD TG-5HT GC Columns offer extended operation up to 400°C, ideal for high temperature GC applications.
| Max. Temperature | 380/400°C |
|---|---|
| Stationary Phase | TraceGOLD™ TG-5 HT |
| Polarity | Low-Polar |
| For Use With (Application) | Pesticides Analysis,GC/MS for Pesticides,GC/MS for Residual Solvents, Solvents, and Solvent Impurities |
| USP Type | G27, G36 |
| Product Line | TraceGOLD |