Gel Filtration Media and Columns
- (3)
- (2)
- (2)
- (1)
- (3)
- (1)
- (3)
- (2)
- (1)
- (6)
- (2)
- (8)
- (6)
- (3)
- (5)
- (9)
- (2)
- (1)
- (7)
- (2)
- (11)
- (3)
- (6)
- (1)
- (1)
- (3)
- (10)
- (1)
- (1)
- (2)
- (1)
- (2)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (3)
- (1)
- (1)
- (1)
- (1)
- (1)
- (4)
- (1)
- (16)
- (2)
- (9)
- (2)
- (2)
- (3)
- (10)
- (4)
- (1)
- (2)
- (2)
- (1)
- (2)
- (1)
- (2)
- (5)
- (1)
- (1)
- (2)
- (1)
- (3)
- (3)
- (1)
- (2)
- (2)
- (1)
- (8)
- (1)
- (5)
- (1)
- (5)
- (1)
- (1)
- (1)
- (1)
- (4)
- (1)
- (1)
- (5)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (4)
- (2)
- (1)
- (1)
- (1)
- (1)
- (3)
- (2)
- (3)
Filtered Search Results
Cytiva Gel Filtration Calibration Kits
Calibrate gel filtration columns simply, reliably. Cytiva Life Sciences™ Gel Filtration Calibration Kits contain a well-defined series of protein standards.
| Content And Storage | 2° to 8°C |
|---|---|
| Product Type | Calibration Kit |
| For Use With (Equipment) | High-resolution media and prepacked column |
| Quantity | Each |
| For Use With (Application) | Calibration of high-resolution gel filtration media and column such as Superdex™, Superose and Sephacryl |
Cytiva Sephadex™ G-25 Media
Use of Sephadex™ is well established as a gel filtration medium for desalting and buffer exchange in industrial applications. Cytiva Life Sciences™ Sephadex™ G-25 Media quickly desalts, removes contaminants and transfers to a new buffer in a single step.
| Height (Metric) | 30cm |
|---|---|
| Content And Storage | 4 to 30°C, dry resins. Used resins 4 to 8 °C in 20% Ethanol or 0.01 M NaOH |
| Bed Volume | 4 to 6mL/g in Distilled Water |
| Format | Solid Spherical Bead |
| pH Range | 2 to 13 |
| Product Type | Sephadex G-25 Media |
| Diameter (Metric) Inner | 2.6cm |
| For Use With (Application) | Desalting and Buffer exchange and removal free label in industrial applications |
| Support Type | Cross-linked Dextran |
| Height (English) | 11.81 in. |
Cytiva Sephadex™ G50 Superfine Media
Use as a well established gel filtration medium for desalting and buffer exchange of biomolecules >30 000 molecular weight. Sephadex™ G50 Superfine Media's small bead size gives higher efficiency.
Cytiva HiTrap™ Heparin HP Columns
Purify DNA-binding proteins, coagulation factors, lipoproteins and protein synthesis factors. Cytiva Life Sciences™ HiTrap™ Heparin HP Columns are prepacked with Heparin Sepharose™ High Performance for high-resolution purification.
| Particle Size | 34 μm |
|---|---|
| Ligand Type | 10mg Heparin/mL medium |
| Height (Metric) | 2.5cm |
| Content And Storage | 4° to 30°C |
| pH Range | 5 to 10 |
| Product Type | Heparin HP Column |
| For Use With (Equipment) | Syringe, peristaltic pump or liquid chromato graphy system such as AKTA™ design or FPLC system |
| Material | Polypropylene |
| For Use With (Application) | Purification of Antithrombin III, coagulation facto rs and other Plasma Proteins |
| Support Type | 6% Highly Cross-linked Agarose |
| Max. Pressure | 42psi |
| Height (English) | 0.98 in. |
Cytiva Superdex™ 200 Increase 10/300 GL Prepacked Tricorn™ Columns
For size exclusion chromatography and analysis of proteins with molecular weights between 10,000 and 600,000. Cytiva Lifescience™ Superdex™ 200 Increase 10/300 GL Prepacked Tricorn™ Columns are designed for small scale preparative purification.
Thermo Scientific™ POROS™ GoPure™ 50 D Pre-packed Column, 0.5 x 5 cm, 1 mL
Thermo Scientific™ POROS™ GoPure™ 0.5 cm pre-packed columns are intended for the screening of POROS ion exchange resins or for small scale purification.
Cytiva HiTrap™ Streptavidin HP Column
Use for fast and easy preparative purifications either alone or connected in series. HiTrap™ Streptavidin HP Column are convenient and reliable prepacked columns.
Cytiva Superdex™ 200 Increase 5/150 GL Prepacked Tricorn™ Columns
For size exclusion chromatography and analysis of proteins with molecular weights between 10,000 and 600,000. Cytiva Lifescience™ Superdex™ 200 Increase 5/150 GL Prepacked Tricorn™ Columns are designed for small scale preparative purification.
Cytiva HiTrap™ Capto™ Core 400
Designed for intermediate purification and polishing of viruses and other large biomolecules
Cytiva Sepharose Agarose Gel Filtration Media
Choose from a wide range of bead-formed agarose-based gel filtration media. Cytiva Life Sciences™ Sepharose Agarose Gel Filtration Media shows good separation over a wide molecular weight range.
| Format | Solid Bead |
|---|---|
| Product Type | Sepharose Agarose Gel Filtration Media |
| Quantity | 1 L |
| For Use With (Application) | Allow characterization or cleaning up of samples containing components of diverse molecular weight |
Cytiva HiTrap™ Blue HP Columns
For purifying albumin, enzymes including NAD+ and NADP+, coagulation factors, interferons and related proteins
| Particle Size | 34 μm |
|---|---|
| Height (Metric) | 2.5cm |
| Content And Storage | 4° to 30°C |
| pH Range | 4 to 12 |
| Product Type | Blue HP Columns |
| For Use With (Equipment) | Syringe, peristaltic pump or liquid chromato graphy system such as AKTA™ design or FPLC system |
| Sample Type | Albumin, Interferon, Nucleotide-dependent Enzymes, a2-macroglobulin, Coagulation Factors and Related Proteins |
| Material | Polypropylene |
| For Use With (Application) | Purifying wide range of biomolecules, including albumin, interferon, a broad range of nucleotide-dependent Enzymes, alpha2-macroglobulin, coagulation facto rs and related Proteins |
| Support Type | 6% Highly Cross-linked Agarose |
| Max. Pressure | 42psi |
| Height (English) | 0.98 in. |
Cytiva Sephacryl™ S-300 High Resolution Media
Offer good recovery and low nonspecific adsorption. Hydrophilic, rigid allyl dextran/bisacrylamide matrix for fast and reproducible purification of proteins, polysaccharides and other macromolecules. Enable gel filtration at laboratory and industrial scale, and may be purchased in pre-packed columns.
Cytiva Sephadex™ G-25 DNA Grade SF Cleanup Gel
Tested to ensure reproducibly high recovery of DNA (10 bases in length) from small molecules by gel filtration