Filtered Search Results
Invitrogen™ SuperScript™ IV First-Strand Synthesis System
The SuperScript IV First-Strand Synthesis System for RT-PCR, available with or without ezDNase, is optimized for synthesis of first-strand cDNA from purified poly(A)+ or total RNA.
| GC-Rich PCR Performance | High |
|---|---|
| Format | Kit |
| Reverse Transcriptase | SuperScript IV |
| Size (Final Product) | Up to 12.3 kb |
| Reaction Format | Separate components |
| Final Product Type | First-Strand cDNA |
| Reaction Speed | 10 min. |
| Reagent Type | Reverse Transcription |
| Quantity | Each |
| Optimal Reaction Temperature | 50°C |
| Technique | Reverse Transcription |
| Starting Material | RNA |
Invitrogen™ Qubit™ microRNA Assay Kits
Achieve accurate miRNA quantitation, even in the presence of rRNA, large mRNA, or contaminants, with the Qubit microRNA Assay Kit, which offers 100 and 500 assay formats.
| Excitation/Emission | 498/518 |
|---|---|
| Shipping Condition | Room Temperature |
| Product Type | microRNA Assay Kit |
| For Use With (Equipment) | Qubit Fluorometer |
| For Use With (Application) | microRNA Quantitation |
| Product Line | Qubit |
| Detection Method | Fluorescence |
Invitrogen™ Platinum™ SuperFi II PCR Master Mixes
Invitrogen Platinum SuperFi II PCR Master Mix (2X) is a ready-to-use mixture of Platinum SuperFi II DNA Polymerase, Platinum SuperFi II Buffer, and dNTPs for convenient PCR setup and efficient amplification.
| Shipping Condition | Dry Ice |
|---|---|
| Polymerase | Platinum SuperFi II DNA Polymerase |
| GC-Rich PCR Performance | High |
| Fidelity (vs. Taq) | >300X |
| Size (Final Product) | 20 kb or less |
| Reaction Format | SuperMix or Master Mix |
| Product Type | PCR Master Mix |
| Reaction Speed | Fast |
| Hot Start | Built-In Hot Start |
| Overhang | Blunt |
| Concentration | 2X |
| For Use With (Application) | Hot-start PCR,High-fidelity PCR |
Thermo Scientific™ FastDigest BglII
Cut at A^GATCT sites with FastDigest™ BglII restriction enzyme, which performs best at 37°C in 5-15 minutes using universal FastDigest Buffer.
| Sensitive to Heat Inactivation | No |
|---|---|
| Product Type | Restriction Enzyme |
| Enzyme | Bgl II |
| Methylation Sensitivity | Not Dam Methylation-Sensitive,Not Dcm Methylation-Sensitive,Not CpG Methylation-Sensitive |
| Research Category | Traditional Cloning |
| Compatible Buffer | 10X FastDigest Buffer/FastDigest Green Buffer |
| Overhang | 5' protruding ends |
| Type IIS RE | No |
| Optimal Reaction Temperature | 37°C |
| Product Line | FastDigest |
Thermo Scientific™ Phusion U Hot Start PCR Master Mix
Thermo Scientific Phusion U DNA polymerase is a novel engineered high fidelity enzyme developed using fusion technology.
| Shipping Condition | Dry Ice |
|---|---|
| Polymerase | Phusion U Hot Start DNA Polymerase |
| GC-Rich PCR Performance | Medium |
| Content And Storage | • Phusion U Hot Start DNA Polymerase • 2X reaction buffer • 3 mM MgCl2 • 400 μM each of dATP, dTTP, dCTP and dGTP Master mix is supplied with nuclease-free water. Store at -20°C. |
| Fidelity (vs. Taq) | 25X |
| Size (Final Product) | 20 kb or less |
| Reaction Format | SuperMix or Master Mix |
| Product Type | Hot Start PCR Master Mix |
| Reaction Speed | Fast |
| Hot Start | Built-In Hot Start |
| Overhang | Blunt |
| Concentration | 2X |
| For Use With (Application) | Hot-start PCR |
Thermo Scientific™ HindIII (10 U/μL)
The HindIII restriction enzyme recognizes A^AGCTT sites and cuts best at 37°C in R buffer.
| Concentration | 10 U/μL |
|---|
Invitrogen™ GeneArt™ Gibson Assembly HiFi Master Mix
GeneArt Gibson Assembly HiFi Master Mix enables DNA assembly and cloning via a technique that allows multiple overlapping DNA fragments to be seamlessly linked in a one-step, 15–60 minute isothermal reaction.
| Shipping Condition | Ambient, Wet Ice, Dry Ice |
|---|---|
| Content And Storage | Includes master mix, positive control, and water and accommodates the use of your own competent cells. |
| Workflow Step | DNA Assembly |
| Number of Fragments | Up to 6 fragments |
| Product Type | HiFi Master Mix |
| Control Type | Positive Control |
| Cloning Method | Seamless cloning |
| For Use With (Application) | Seamless Cloning & Genetic Assembly |
| Product Line | GENEART |
Invitrogen™ RNase Cocktail™ Enzyme Mix
Endonuclease-free, exonuclease-free, protease-free
| Shipping Condition | Dry Ice |
|---|---|
| Product Type | RNAse Cocktail Enzyme Mix |
| Enzyme | RNase |
| Product Line | Ambion |
Thermo Scientific™ DreamTaq DNA Polymerase (5 U/μL)
Thermo Scientific DreamTaq DNA Polymerase is an enhanced Taq DNA polymerase optimized for all standard PCR applications. It ensures higher sensitivity, longer PCR products, and higher yields compared to conventional Taq DNA polymerase.
| Polymerase | DreamTaq DNA Polymerase |
|---|---|
| GC-Rich PCR Performance | Low |
| Fidelity (vs. Taq) | 1X |
| Reaction Speed | Standard |
| Hot Start | No |
| Overhang | 3'-A |
| Concentration | 5 U/μL |
Invitrogen™ AccuPrime™ Taq DNA Polymerase, High Fidelity
Invitrogen AccuPrime Taq DNA Polymerase, High Fidelity, provides qualified reagents for the high-fidelity PCR amplification of nucleic acid templates.
| Shipping Condition | Dry Ice |
|---|---|
| Polymerase | AccuPrime Taq DNA Polymerase High Fidelity |
| GC-Rich PCR Performance | Low |
| Fidelity (vs. Taq) | 9X |
| Size (Final Product) | 20 kb or less |
| Reaction Format | Separate Components |
| Product Type | DNA Polymerase |
| Reaction Speed | Standard |
| Hot Start | Built-In Hot Start |
| For Use With (Application) | Hot-start PCR,High-fidelity PCR |
| Detection Method | Primer-probe |
DreamTaq™ Hot Start PCR Master Mixes
Thermo Scientific DreamTaq Hot Start PCR Master Mix is a ready-to-use 2X reaction mix that includes DreamTaq Hot Start DNA Polymerase, DreamTaq buffer, magnesium, and dNTPs.
| Shipping Condition | Dry Ice |
|---|---|
| Polymerase | DreamTaq DNA Polymerase |
| GC-Rich PCR Performance | Low |
| Reaction Format | SuperMix or Master Mix |
| Reaction Speed | Standard |
| Hot Start | Built-In Hot Start |
| Overhang | 3'-A |
| Concentration | 2X |
| For Use With (Application) | Hot-start PCR |
Applied Biosystems™ Power SYBR™ Green RNA-to-CT™ 1-Step Kit
The novel formulation reduces false positive results caused by primer dimers, significantly improves data accuracy, and provides reliable detection of low abundance targets.
| Shipping Condition | Wet Ice |
|---|---|
| Purity or Quality Grade | UP (Ultra Pure) |
| Reverse Transcriptase | ArrayScript™ UP |
| For Use With (Application) | Gene Expression |
| PCR Method | 1-step RT-qPCR |
| Detection Method | SYBR |
| Polymerase | AmpliTaq Gold DNA Polymerase |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT System, QuantStudio™ 12k Flex, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7, StepOne™, StepOnePlus™, ViiA™ 7 System |
| Sample Type | RNA |
| Reaction Speed | Standard |
| Label or Dye | SYBR Green |
| Run Time | Standard |
| Product Line | RNA-to-CT, SYBR |
Thermo Scientific™ Phusion™ Plus PCR Master Mixes
Thermo Scientific Phusion Plus PCR Master Mix is a convenient, ready-to-use 2X mixture of Phusion Plus DNA Polymerase, buffer, magnesium chloride, and dNTPs.
| Shipping Condition | Dry Ice |
|---|---|
| Polymerase | Phusion Plus DNA Polymerase |
| GC-Rich PCR Performance | High |
| Fidelity (vs. Taq) | >100X |
| Size (Final Product) | 20 kb or less |
| Reaction Format | Ready to use master mix |
| Reaction Speed | 15 to 30 sec./kb |
| Hot Start | Built-In Hot Start |
| Overhang | Blunt |
| Concentration | 2X |
| For Use With (Application) | Hot-start PCR,High-fidelity PCR |
Applied Biosystems™ TaqPath™ ProAmp™ Master Mix
TaqPath ProAmp Master Mix is for high-throughput genotyping and copy number variation protocols requiring uncompromising reliability and accuracy, even in the presence of inhibitors commonly found in clinical samples.
| Shipping Condition | Wet Ice |
|---|---|
| Content And Storage | Store at 2°C to 8°C in the dark. |
| InhibitorToleranceSimple | Very High |
| For Use With (Application) | Genotyping |
| PCR Method | qPCR |
| Multiplex Capability | Up to 3-plex, Up to 4-plex |
| Detection Method | Primer-probe |
| Includes | dUTP, UNG/UDG |
| Thermostability | 72 hr., Assembled Reaction |
| Polymerase | Taq DNA Polymerase |
| Product Type | qPCR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7500 Fast System, QuantStudio 12k Flex, QuantStudio 3, QuantStudio 5, QuantStudio 6 Flex, QuantStudio 7 Flex, ViiA 7 System, ViiA 7 Dx, QuantStudio Dx, StepOnePlus System, StepOne System |
| Reaction Speed | Fast or Standard |
| Target Specificity | cDNA or gDNA only |
| Product Line | TaqPath |
Invitrogen™ Platinum™ II Hot-Start PCR Master Mixes (2X)
Invitrogen Platinum II Hot-Start PCR Master Mix (2X) offers Platinum II Taq Hot-Start DNA Polymerase premixed with Platinum II PCR buffer and dNTPs for convenient PCR setup.
| GC-Rich PCR Performance | High |
|---|---|
| Fidelity (vs. Taq) | 1X |
| Format | Tube |
| Size (Final Product) | 5 kb or less |
| Hot Start | Built-In Hot Start |
| Concentration | 2X |
| For Use With (Application) | Hot-start PCR |