Multiparameter Meters
- (2)
- (16)
- (4)
- (4)
- (9)
- (22)
- (4)
- (12)
- (1)
- (3)
- (8)
- (1)
- (1)
- (1)
- (70)
- (6)
- (2)
- (1)
- (3)
- (1)
- (35)
- (4)
- (1)
- (3)
- (12)
- (3)
- (1)
- (5)
- (7)
- (2)
- (3)
- (1)
- (1)
- (24)
- (1)
- (1)
- (4)
- (7)
- (11)
- (2)
- (27)
- (8)
- (9)
- (2)
- (2)
- (35)
- (1)
- (14)
- (5)
- (2)
- (1)
- (1)
- (10)
- (1)
- (3)
- (2)
- (3)
- (3)
- (3)
- (7)
- (6)
- (3)
- (2)
- (8)
- (3)
- (9)
- (103)
- (1)
- (6)
- (4)
- (1)
- (8)
- (9)
- (1)
- (33)
- (6)
- (2)
- (1)
- (1)
- (5)
- (5)
- (8)
- (14)
- (81)
- (29)
- (8)
- (4)
- (8)
- (15)
- (32)
- (11)
- (16)
- (1)
- (40)
- (16)
- (6)
- (2)
- (9)
- (33)
- (18)
- (8)
- (3)
- (43)
- (2)
- (44)
- (56)
- (1)
- (1)
- (79)
- (132)
- (5)
- (2)
- (6)
- (4)
- (54)
- (96)
Filtered Search Results
Thermo Scientific™ Elite PCTS pH / Conductivity / TDS / Salinity Pocket Testers and Replacement Sensors
Flexible on-the-go pH, conductivity, TDS, salinity and temperature testing using durable Elite PCTS pocket testers for a variety of applications including agriculture, aquaculture, hydroponics and more!
| Salinity Measurement Modes | Per practical salinity curve |
|---|---|
| Temperature Accuracy | ±0.6°C, ±1.0°F for 0.0 to 50.0°C; ±1.1°C, ±1.9°F for 50.1 to 60.0°C |
| Resolution (Conductivity) | 0.1 μS/cm for 0.0 to 200.0 μS/cm; 1 μS/cm for200 to 2000 μS/cm; 0.01 mS/cm for 2.00 to 20.00 mS/cm |
| Range (Conductivity) | 0.00 to 20.00 mS/cm |
| Range (TDS) | 0.00 to 10.00 ppt |
| Measurement Modes | pH,Conductivity,TDS,Salinity,Temperature |
| Resolution (TDS) | 0.1 ppm for 0.0 to 100.0 ppm; 1 ppm for 100 to 1000 ppm; 0.01 ppt for 0.10 to 10.00 ppt |
| Range (pH) | -1.00 to 15.00 |
| TDS Factor Range | 0.40 to 1.00 (selectable) |
| Accuracy (pH) | ±0.02 |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Range (Salinity) | 0.00 to 10.00 ppt |
| Temperature Compensation | Yes |
| Accuracy (TDS) | ± 1% full scale |
| Accuracy (Salinity) | ± 1% full scale |
| Resolution (Salinity) | 0.10 ppt |
| Accuracy (Conductivity) | ± 1% full scale |
| Temperature Range (English) | 32.0°F to 140.0°F |
| Calibration Points (pH) | 1 to 3 |
| Calibration Modes | pH, conductivity, TDS, salinity, temperature |
| Temperature Probe Calibration | 1 point |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Resolution | 0.1°C, 0.1°F |
| Calibration Points (Conductivity) | 1 to 3 |
Thermo Scientific™ Elite CTS Conductivity / TDS / Salinity Cup-sensor Pocket Testers and Replacement Sensors
Flexible on-the-go conductivity, TDS, salinity and temperature testing using durable Elite CTS cup-sensor pocket testers for a variety of applications including agriculture, aquariums and more!
| Salinity Measurement Modes | Per practical salinity curve |
|---|---|
| Temperature Accuracy | ±0.6°C, ±1.0°F for 0.0 to 50.0°C; ±1.1°C, ±1.9°F for 50.1 to 60.0°C |
| Resolution (Conductivity) | 0.1 μS/cm for 0.0 to 200.0 μS/cm; 1 μS/cm for200 to 2000 μS/cm; 0.01 mS/cm for 2.00 to 20.00 mS/cm |
| Range (Conductivity) | 0.00 to 20.00 mS/cm |
| Range (TDS) | 0.00 to 10.00 ppt |
| Measurement Modes | Conductivity,TDS,Salinity,Temperature |
| Resolution (TDS) | 0.1 ppm for 0.0 to 100.0 ppm; 1 ppm for 100 to 1000 ppm; 0.01 ppt for 0.10 to 10.00 ppt |
| TDS Factor Range | 0.40 to 1.00 (selectable) |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Range (Salinity) | 0.00 to 10.00 ppt |
| Temperature Compensation | Yes |
| Accuracy (TDS) | ± 1% full scale |
| Accuracy (Salinity) | ± 1% full scale |
| Resolution (Salinity) | 0.10 ppt |
| Accuracy (Conductivity) | ± 1% full scale |
| Temperature Range (English) | 32.0°F to 140.0°F |
| Temperature Probe Calibration | 1 point |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Resolution | 0.1°C, 0.1°F |
| Calibration Points (Conductivity) | 1 to 3 |
Eutech Expert pH Pocket Tester
Perform on-the-go, fuss-free measurements for applications such as water treatment, environmental monitoring, education, hydroponics, agriculture, aquaculture, food & beverage and many more!
Thermo Scientific™ Elite pH Spear Pocket Testers and Replacement Sensors
Flexible on-the-go pH testing using durable Elite spear pocket testers with replaceable sensors for a variety of applications include food, beverage, agriculture and more!
| Temperature Accuracy | Manual input |
|---|---|
| Temperature Range (English) | 32.0°F to 140.0°F |
| Measurement Modes | pH |
| Range (pH) | -1 to 15 |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | 0.0°C to 60.0°C |
| Accuracy (pH) | ±0.02 |
| Temperature Resolution | 0.1°C, 0.1°F |
Thermo Scientific™ Elite pH Pocket Testers and Replacement Sensors
Flexible on-the-go pH and temperature testing using durable Elite pocket testers with replaceable sensors for a variety of applications including environmental monitoring, pools, spas and more!
Thermo Scientific™ Orion™ Pro Star PC215 pH/ion and Conductivity Bench Meter with Stand
Designed to provide accurate and reliable pH, ORP, ion concentration, conductivity, TDS, salinity, resistivity and temperature analysis, the Thermo Scientific™ Orion™ Pro Star PC215 bench meter is well suited for laboratories that desire a modern meter with advance performance.
| Salinity Measurement Modes | Natural Seawater (ppt), Practical Salinity Units (PSU), or % NaCl |
|---|---|
| Range (Resistivity) | 1.0 Ω to 100.0 MΩ |
| Memory | Non-volatile |
| Advanced ISE Functions | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
| Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
| Resolution (ISE) | 0.0001 minimum, 1 to 5 digits |
| Display Type | 7-in. High-resolution Color Graphic LCD |
| Resolution (mV) | 0.1 mV |
| Resolution (Ion) | 0.0001 minimum, 1 to 5 digits |
| Data Points | 10,000 with Date and Time Stamp |
| Temperature Probe Calibration | 1 or 2 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Accuracy (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Warranty | 2 year meter warranty |
| Temperature Accuracy | ±0.3°C, ±0.5°F |
| Calibration Points (ISE) | Up to 5 |
| Resolution (Conductivity) | 0.001 μS/cm minimum, auto-ranging, up to 4 digits |
| Range (Conductivity) | 0.010 μS/cm to 3000 mS/cm |
| Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Dimensions (L x W x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
| Accuracy (TDS) | ±0.5% reading |
| Temperature Selection | Automatic with ATC temperature sensor, ambient or manual |
| Keypad | Capacitive touchscreen user interface |
| Outputs | USB flash drive, computer or printer (STARA-106) |
| Temperature Range (English) | -22.0°F to +266.0°F |
| Range (Relative mV) | -2000 to 2000 mV |
| Calibration Points (pH) | 1 to 5 points |
| Backlight Option | Yes |
| Range (mV) | -2000 to 2000 mV |
| Range (ORP) | -2000 to 2000 mV |
| Methods | 10 per channel (20 total) |
| Cell Constant | 0.100 cm-1, 0.475 cm-1, 0.550 cm-1, 1.000 cm-1, 10.00 cm-1 or user-defined from 0.001 to 199.9 cm-1 |
| Temperature (Metric) Reference | 5, 10, 15, 20, 25 or 30°C |
| Range (pH) | -2 to 20 |
| TDS Factor Range | Linear (0.01 to 10.00), ISO/EN 27888, 442, NaCl |
| Channels | 2 |
| Accuracy (pH) | ±0.002 pH |
| Range (ISE) | 0.0001 to 19999 |
| Range (Salinity) | 0.010 to 80.00 ppt; 0.01 to 42.00 PSU; or 0.01 to 400.0% NaCl |
| Temperature Compensation | Linear (0.00 to 10.00 %/°C), nLFn (non-linear natural water), nLFu (non-linear ultra-pure water), EP/USP or off |
| Accuracy (Salinity) | ±0.5% reading |
| Resolution (Salinity) | 0.001 ppt minimum; 0.01 PSU minimum; or 0.01% NaCl minimum, auto-ranging |
| Accuracy (Conductivity) | ±0.5% reading |
| Inputs | Channel 1: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference; Channel 2: 8-pin MiniDIN for conductivity with ATC |
| Weight (Metric) | 1.00 kg |
| Resolution (ORP) | 0.1 mV |
| Calibration Points (Conductivity) | 1 to 5 points |
| Resolution (Resistivity) | 0.1 Ω minimum, auto-ranging |
| Isopotential Point | 7.000 pH; 1.000 ion concentration |
| Accuracy (Resistivity) | ±0.5% reading |
| AC Adapter | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Range (TDS) | 0.010 ppm to 500.0 ppt (TDS factor of 1.00); or 0.010 mg/L to 500.0 g/L (TDS factor of 1.00) |
| Resolution (TDS) | 0.001 ppm or mg/L minimum, auto-ranging, up to 4 digits |
| Calibration | pH, ORP, Ion Concentration, Conductivity, TDS, Salinity, Temperature |
| Accuracy (ORP) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Calibration Points | 1 to 5 (pH), 1 (ORP), 1 to 5 (ion), 1 to 5 (conductivity), 1 to 5 (TDS), 1 (salinity), 1 to 2 (temperature) |
| Alarm Output | Calibration reminder alarm, high and low limit alarm per parameter |
| IP Rating | IP54 |
| Weight (English) | 2.20 lbs. |
| Range (Ion) | 0.0001 to 19999 |
| Temperature Range (Metric) | -30.0°C to +130.0°C |
| Temperature Resolution | 0.1°C, 0.1°F |
Thermo Scientific™ Eutech™ ECTestr11+ Multi Range Conductivity Tester
Get quick and accurate conductivity measurements in the field, laboratories, and schools.
Thermo Scientific™ Orion™ Versa Star Pro™ pH/ISE Benchtop Multiparameter Meter
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Get premium performance and ultimate flexibility with our benchtop meter with pH/ISE module for pH, ion concentration, and temperature.
| Power Rating | DC input: 9VDC, 1A |
|---|---|
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
| Advanced ISE Functions | Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit |
| Languages | English, Spanish, French, Italian, German, Chinese, Portuguese and Korean |
| Measurement Modes | pH,mV,Relative mV,ORP,Ion Concentration (ISE) with Temperature |
| Range (pH) | -2 to 20 |
| Resolution (ISE) | 0.0001 minimum, 1 to 4 significant digits (user selectable) |
| Channels | 4 (Customizable with modules) |
| Accuracy (pH) | ±0.002 |
| Range (ISE) | 0.0001 to 19990 with selectable units of ppm, Molar, mg/L, %, ppb or none |
| Power Supply | Universal AC adapter (included) |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Display Type | Color graphic LCD with user-customizable options |
| Resolution (mV) | 0.1mV |
| Data Points | 2000 with Date and Time Stamp |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Weight (Metric) | 1.2 kg, modules add 0.2 kg each |
| Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Warranty | 3 year meter and module warranty |
| Temperature Accuracy | ±0.1°C |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Calibration Points (ISE) | 1 to 6 |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Isopotential Point | 7.000pH (adjustable), 1.000 ISE (adjustable) |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR) |
| Log Function Type | Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with |
| Calibration | pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
| Alarm Output | Set point alarm, high/low limit alarm, calibration due alarm |
| Dimensions (L x W x H) | 28cm x 24cm x 10cm (11 in. x 9.5 in. x 3.9 in.), modules add ≤ 2cm (0.8 in.) L & H |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| IP Rating | IP54 |
| Keypad | Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB (2), RS232 |
| Temperature Range (English) | 22.0°F to 221.0° F |
| Range (Relative mV) | ±2000.0 mV |
| Calibration Points (pH) | 1 to 6 |
| Backlight Option | Yes |
| Weight (English) | 2.5 lb., modules add 0.5 lb. each |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5.0°C to +105.0°C |
| Range (mV) | ±2000.0 mV |
| Range (ORP) | ±2000.0 mV |
| Methods | 10 per channel |
| Temperature Resolution | 0.1°C, 0.1°F |
Fisherbrand™ accumet™ AR450 pH/ion/Conductivity Meter Kit
Designed to deliver precise and reliable electrochemistry testing, the accumet AR450 offers enhanced performance in a streamlined design. Ideal for laboratories requiring dependable measurement capabilities.
Thermo Scientific™ Eutech™ SALTTEST11 Salinity Meter
Get quick and accurate salinity measurements in the field, laboratories, and schools.
Thermo Scientific™ Eutech™ PC 450 Meter with pH /Con/ATC Electrodes
Eutech™ offers a wide range of pH meters and electrodes that measure pH values in various educational, laboratory and industrial applications.
Thermo Scientific™ Orion Star™ A321 pH Portable Meter
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Accurately monitor pH, mV, ORP and temperature with our waterproof, portable pH meter for high performance in challenging field locations.
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
|---|---|
| Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
| Measurement Modes | pH,mV,Relative mV,ORP with Temperature |
| Range (pH) | -2 to 20 |
| Channels | 1 |
| Accuracy (pH) | ±0.002 |
| Power Supply | 4 AA batteries (included) or universal AC adapter (sold separately) |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Battery Life | 800 hr. |
| Display Type | LCD Graphic, Backlit |
| Resolution (mV) | 0.1mV |
| Data Points | 5000 with Date and Time Stamp |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Inputs | BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe) |
| Weight (Metric) | 0.5 kg |
| Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Warranty | 3 Year Meter |
| Temperature Accuracy | ±0.1°C |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Isopotential Point | 7.000pH |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003) |
| Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
| Calibration | pH with calibration editing option, relative mV (RmV), ORP and temperature |
| Battery Type | 4 x AA |
| Relative Humidity Range | 5 to 85%, non-condensing |
| Calibration Points | 1 to 5 |
| Alarm Output | High/low limit alarm, calibration due alarm |
| Dimensions (L x W x H) | 24cm x 10cm x 6.5cm (9.5 in. x 3.9 in. x 2.6 in.) |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| IP Rating | IP67 |
| Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
| Model | Orion Star A321 pH/mV/RmV/ORP/Temperature Portable Meter |
| Outputs | USB, RS-232 |
| Temperature Range (English) | 22.0°F to 221.0° F |
| Range (Relative mV) | ±2000.0 mV |
| Backlight Option | Yes (Selectable) |
| Weight (English) | 1.2 lb. |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5.0°C to +105.0°C |
| Range (mV) | ±2000.0 mV |
| Range (ORP) | ±2000.0 mV |
| Methods | 10 per channel with password protection |
| Temperature Resolution | 0.1°C, 0.1°F |
Thermo Scientific™ Orion Star™ A324 pH/ISE Portable Multiparameter Meter
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Accurately monitor pH, ion concentration, mV, ORP and temperature with our pH/ISE portable meter for challenging field testing.
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
|---|---|
| Advanced ISE Functions | Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit |
| Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
| Measurement Modes | pH,mV,Relative mV,ORP,Ion Concentration (ISE) with Temperature |
| Resolution (ISE) | 0.0001 minimum, 1 to 3 significant digits (user selectable) |
| Power Supply | 4 AA batteries (included) or universal AC adapter (sold separately) |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Battery Life | 800 hr. |
| Display Type | LCD Graphic, Backlit |
| Resolution (mV) | 0.1mV |
| Data Points | 5000 with Date and Time Stamp |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Warranty | 3 Year Meter |
| Temperature Accuracy | ±0.1°C |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Calibration Points (ISE) | 1 to 5 |
| Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
| Battery Type | 4 AA (included) |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Dimensions (L x W x H) | 24cm x 10cm x 6.5cm (9.5 in. x 3.9 in. x 2.6 in.) |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB, RS232 |
| Temperature Range (English) | 22.0°F to 221.0° F |
| Range (Relative mV) | ±2000.0 mV |
| Calibration Points (pH) | 1 to 5 |
| Backlight Option | Yes (Selectable) |
| Range (mV) | ±2000.0 mV |
| Range (ORP) | ±2000.0 mV |
| Methods | 10 per channel with password protection |
| Range (pH) | -2 to 20 |
| Channels | 1 |
| Accuracy (pH) | ±0.002 |
| Range (ISE) | 0.0001 to 19900 with selectable units of ppm, Molar, mg/L, %, ppb or none |
| Inputs | BNC (pH, ORP or ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe) |
| Weight (Metric) | 0.5 kg |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Isopotential Point | 7.000pH |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003) |
| Calibration | pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ |
| Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
| Alarm Output | High/low limit alarm, calibration due alarm |
| IP Rating | IP67 |
| Model | Orion Star A324 pH/ISE/mV/RmV/ORP/Temperature Portable Meter |
| Weight (English) | 1.2 lb. |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5.0°C to +105.0°C |
| Temperature Resolution | 0.1°C, 0.1°F |
| Accuracy (ISE) | 0.5% full scale (monovalent ion), 1% full scale (divalent ion) |
|---|---|
| Temperature Accuracy | ±0.3°C, ±0.5°F |
| Calibration Points (ISE) | 2 to 8 |
| Measurement Modes | pH,Ion,Redox |
| Range (pH) | -2 to 20 |
| Range (Concentration) | 0.001 to 19999 ppm (±2000 mV) |
| Accuracy (ORP) | ±0.2 mV |
| Resolution (ISE) | 2 or 3 digits |
| Accuracy (pH) | ±0.002 + 1 LSD |
| Power Supply | 9 V DC adapter, 1.3 A (100/240 VAC, SMPS) |
| Includes | Integral Electrode Holder & 100/240 VAC Adapter and RS232 cable |
| Calibration Points | Up to 6 preset or 5 custom |
| Temperature Compensation | ATC / MTC (0 to 100 °C) (pH only) |
| Outputs | RS232 |
| Temperature Range (English) | 32.0°F to 212.0°F |
| Range (Relative mV) | ±2000.0 mV |
| Calibration Points (pH) | Up to 6 preset or 5 custom |
| Temperature Range (Metric) | 0.0°C to 100.0°C |
| Range (mV) | ±2000.0 mV |
| Range (ORP) | ±2000.0 mV |
| Range (DO) | ±2000.0 mV |
| Temperature Resolution | 0.1 °C / 0.1 °F |
| Resolution (ORP) | 0.1 mV |
Thermo Scientific™ Orion™ Pro Star PD216 pH/ion and DO Bench Meter
Designed to provide accurate and reliable pH, ORP, ion concentration, dissolved oxygen, barometric pressure and temperature analysis, the Thermo Scientific™ Orion™ Pro Star PD216 bench meter is well suited for laboratories that desire a modern meter with advance performance.
| Resolution (Polarographic DO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
|---|---|
| Pressure Range | 400.0 to 850.0 mmHg; 0.533 to 1.133 bar |
| Memory | Non-volatile |
| Advanced ISE Functions | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
| Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
| Measurement Modes | pH,ORP,mV,Ion Concentration (ISE),Dissolved Oxygen (mg/L),Dissolved Oxygen (% Saturation),Temperature,Barometric Pressure |
| Resolution (ISE) | 0.0001 minimum, 1 to 5 digits |
| Barometric Pressure Correction | Yes, automatic with built-in barometer or manual |
| Display Type | 7-in. High-resolution Color Graphic LCD |
| Resolution (mV) | 0.1 mV |
| Resolution (Ion) | 0.0001 minimum, 1 to 5 digits |
| Data Points | 10,000 with Date and Time Stamp |
| Calibration Modes | Water-saturated air (100% and 0% saturation), air-saturated water (100% and 0% saturation) or custom concentration value (Winkler) |
| Temperature Probe Calibration | 1 or 2 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Probe Type | Polarographic or optical DO electrode |
| Salinity Factor | 0.0 to 50.0 ppt |
| Accuracy (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Warranty | 2 year meter warranty |
| Temperature Accuracy | ±0.3°C, ±0.5°F |
| Calibration Points (ISE) | Up to 5 |
| Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Range (RDO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
| Dimensions (L x W x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
| Temperature Selection | Automatic with ATC temperature sensor, ambient or manual |
| Percent Saturation Range (RDO) | 0.0 to 600.0% saturation |
| Keypad | Capacitive touchscreen user interface |
| Outputs | USB flash drive, computer or printer (STARA-106) |
| Temperature Range (English) | -22.0°F to +266.0°F |
| Range (Relative mV) | -2000 to 2000 mV |
| Calibration Points (pH) | 1 to 5 points |
| Backlight Option | Yes |
| Percent Saturation Relative Accuracy (RDO) | ±2% saturation |
| Range (Polarographic DO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
| Range (mV) | -2000 to 2000 mV |
| Accuracy (Barometer) | ±6.0 mmHg; ±0.008 bar |
| Range (ORP) | -2000 to 2000 mV |
| Methods | 10 per channel (20 total) |
| Range (pH) | -2 to 20 |
| Channels | 2 |
| Accuracy (pH) | ±0.002 pH |
| Range (ISE) | 0.0001 to 19999 |
| Resolution (RDO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
| Percent Saturation Resolution (RDO) | 0.1, 1% saturation |
| Resolution (DO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
| Percent Saturation Relative Accuracy (Polarographic DO) | ±2% saturation |
| Inputs | Channel 1: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference; Channel 2: 9-pin MiniDIN for dissolved oxygen with ATC |
| Weight (Metric) | 1.00 kg |
| Resolution (ORP) | 0.1 mV |
| Accuracy (DO) | ±2% saturation; ±0.02 mg/L or ppm |
| Isopotential Point | 7.000 pH; 1.000 ion concentration |
| Accuracy (Polarographic DO) | ±2% saturation; ±0.02 mg/L or ppm |
| AC Adapter | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Calibration | pH, ORP, Ion Concentration, DO, Barometric Pressure, Temperature |
| Accuracy (ORP) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Calibration Points | 1 to 5 (pH), 1 (ORP), 1 to 5 (ion), 1 to 2 (DO), 1 (barometer), 1 to 2 (temperature) |
| Alarm Output | Calibration reminder alarm, high and low limit alarm per parameter |
| IP Rating | IP54 |
| Percent Saturation Resolution (Polarographic DO) | 0.1, 1% saturation |
| Weight (English) | 2.20 lbs. |
| Range (Ion) | 0.0001 to 19999 |
| Temperature Range (Metric) | -30.0°C to +130.0°C |
| Range (DO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
| Percent Saturation Range (Polarographic DO) | 0.0 to 600.0% saturation |
| Temperature Resolution | 0.1°C, 0.1°F |
| Accuracy (RDO) | ±2% saturation; ±0.02 mg/L or ppm |