Multiparameter Meters
- (2)
- (16)
- (4)
- (4)
- (9)
- (22)
- (3)
- (12)
- (1)
- (3)
- (8)
- (1)
- (1)
- (1)
- (70)
- (6)
- (2)
- (1)
- (3)
- (1)
- (35)
- (4)
- (1)
- (3)
- (12)
- (3)
- (1)
- (5)
- (7)
- (2)
- (3)
- (1)
- (1)
- (23)
- (1)
- (1)
- (4)
- (7)
- (11)
- (2)
- (27)
- (8)
- (9)
- (2)
- (2)
- (35)
- (1)
- (14)
- (5)
- (2)
- (1)
- (1)
- (10)
- (1)
- (3)
- (2)
- (3)
- (3)
- (3)
- (7)
- (6)
- (3)
- (2)
- (8)
- (3)
- (9)
- (103)
- (1)
- (6)
- (4)
- (1)
- (8)
- (9)
- (1)
- (33)
- (6)
- (2)
- (1)
- (1)
- (5)
- (5)
- (8)
- (14)
- (80)
- (28)
- (8)
- (4)
- (8)
- (15)
- (32)
- (11)
- (16)
- (1)
- (40)
- (16)
- (6)
- (2)
- (9)
- (33)
- (18)
- (8)
- (3)
- (43)
- (2)
- (44)
- (56)
- (1)
- (1)
- (79)
- (132)
- (4)
- (2)
- (6)
- (3)
- (54)
- (96)
Filtered Search Results
Thermo Scientific™ Elite PCTS pH / Conductivity / TDS / Salinity Pocket Testers and Replacement Sensors
Flexible on-the-go pH, conductivity, TDS, salinity and temperature testing using durable Elite PCTS pocket testers for a variety of applications including agriculture, aquaculture, hydroponics and more!
| Salinity Measurement Modes | Per practical salinity curve |
|---|---|
| Temperature Accuracy | ±0.6°C, ±1.0°F for 0.0 to 50.0°C; ±1.1°C, ±1.9°F for 50.1 to 60.0°C |
| Resolution (Conductivity) | 0.1 μS/cm for 0.0 to 200.0 μS/cm; 1 μS/cm for200 to 2000 μS/cm; 0.01 mS/cm for 2.00 to 20.00 mS/cm |
| Range (Conductivity) | 0.00 to 20.00 mS/cm |
| Range (TDS) | 0.00 to 10.00 ppt |
| Measurement Modes | pH,Conductivity,TDS,Salinity,Temperature |
| Resolution (TDS) | 0.1 ppm for 0.0 to 100.0 ppm; 1 ppm for 100 to 1000 ppm; 0.01 ppt for 0.10 to 10.00 ppt |
| Range (pH) | -1.00 to 15.00 |
| TDS Factor Range | 0.40 to 1.00 (selectable) |
| Accuracy (pH) | ±0.02 |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Range (Salinity) | 0.00 to 10.00 ppt |
| Temperature Compensation | Yes |
| Accuracy (TDS) | ± 1% full scale |
| Accuracy (Salinity) | ± 1% full scale |
| Resolution (Salinity) | 0.10 ppt |
| Accuracy (Conductivity) | ± 1% full scale |
| Temperature Range (English) | 32.0°F to 140.0°F |
| Calibration Points (pH) | 1 to 3 |
| Calibration Modes | pH, conductivity, TDS, salinity, temperature |
| Temperature Probe Calibration | 1 point |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Resolution | 0.1°C, 0.1°F |
| Calibration Points (Conductivity) | 1 to 3 |
Thermo Scientific™ Eutech™ PC 450 Multi-parameter Meter Kit
Measure multiple parameters in a cost-effective and convenient way by using only one Eutech™ multi-parameter meter.
Thermo Scientific™ Elite CTS Conductivity / TDS / Salinity Cup-sensor Pocket Testers and Replacement Sensors
Flexible on-the-go conductivity, TDS, salinity and temperature testing using durable Elite CTS cup-sensor pocket testers for a variety of applications including agriculture, aquariums and more!
| Salinity Measurement Modes | Per practical salinity curve |
|---|---|
| Temperature Accuracy | ±0.6°C, ±1.0°F for 0.0 to 50.0°C; ±1.1°C, ±1.9°F for 50.1 to 60.0°C |
| Resolution (Conductivity) | 0.1 μS/cm for 0.0 to 200.0 μS/cm; 1 μS/cm for200 to 2000 μS/cm; 0.01 mS/cm for 2.00 to 20.00 mS/cm |
| Range (Conductivity) | 0.00 to 20.00 mS/cm |
| Range (TDS) | 0.00 to 10.00 ppt |
| Measurement Modes | Conductivity,TDS,Salinity,Temperature |
| Resolution (TDS) | 0.1 ppm for 0.0 to 100.0 ppm; 1 ppm for 100 to 1000 ppm; 0.01 ppt for 0.10 to 10.00 ppt |
| TDS Factor Range | 0.40 to 1.00 (selectable) |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Range (Salinity) | 0.00 to 10.00 ppt |
| Temperature Compensation | Yes |
| Accuracy (TDS) | ± 1% full scale |
| Accuracy (Salinity) | ± 1% full scale |
| Resolution (Salinity) | 0.10 ppt |
| Accuracy (Conductivity) | ± 1% full scale |
| Temperature Range (English) | 32.0°F to 140.0°F |
| Temperature Probe Calibration | 1 point |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Resolution | 0.1°C, 0.1°F |
| Calibration Points (Conductivity) | 1 to 3 |
Thermo Scientific™ Elite pH Spear Pocket Testers and Replacement Sensors
Flexible on-the-go pH testing using durable Elite spear pocket testers with replaceable sensors for a variety of applications include food, beverage, agriculture and more!
| Temperature Accuracy | Manual input |
|---|---|
| Temperature Range (English) | 32.0°F to 140.0°F |
| Measurement Modes | pH |
| Range (pH) | -1 to 15 |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | 0.0°C to 60.0°C |
| Accuracy (pH) | ±0.02 |
| Temperature Resolution | 0.1°C, 0.1°F |
Thermo Scientific™ Orion™ Pro Star PC215 pH/ion and Conductivity Bench Meter with Stand
Designed to provide accurate and reliable pH, ORP, ion concentration, conductivity, TDS, salinity, resistivity and temperature analysis, the Thermo Scientific™ Orion™ Pro Star PC215 bench meter is well suited for laboratories that desire a modern meter with advance performance.
| Salinity Measurement Modes | Natural Seawater (ppt), Practical Salinity Units (PSU), or % NaCl |
|---|---|
| Range (Resistivity) | 1.0 Ω to 100.0 MΩ |
| Memory | Non-volatile |
| Advanced ISE Functions | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
| Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
| Resolution (ISE) | 0.0001 minimum, 1 to 5 digits |
| Display Type | 7-in. High-resolution Color Graphic LCD |
| Resolution (mV) | 0.1 mV |
| Resolution (Ion) | 0.0001 minimum, 1 to 5 digits |
| Data Points | 10,000 with Date and Time Stamp |
| Temperature Probe Calibration | 1 or 2 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Accuracy (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Warranty | 2 year meter warranty |
| Temperature Accuracy | ±0.3°C, ±0.5°F |
| Calibration Points (ISE) | Up to 5 |
| Resolution (Conductivity) | 0.001 μS/cm minimum, auto-ranging, up to 4 digits |
| Range (Conductivity) | 0.010 μS/cm to 3000 mS/cm |
| Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Dimensions (L x W x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
| Accuracy (TDS) | ±0.5% reading |
| Temperature Selection | Automatic with ATC temperature sensor, ambient or manual |
| Keypad | Capacitive touchscreen user interface |
| Outputs | USB flash drive, computer or printer (STARA-106) |
| Temperature Range (English) | -22.0°F to +266.0°F |
| Range (Relative mV) | -2000 to 2000 mV |
| Calibration Points (pH) | 1 to 5 points |
| Backlight Option | Yes |
| Range (mV) | -2000 to 2000 mV |
| Range (ORP) | -2000 to 2000 mV |
| Methods | 10 per channel (20 total) |
| Cell Constant | 0.100 cm-1, 0.475 cm-1, 0.550 cm-1, 1.000 cm-1, 10.00 cm-1 or user-defined from 0.001 to 199.9 cm-1 |
| Temperature (Metric) Reference | 5, 10, 15, 20, 25 or 30°C |
| Range (pH) | -2 to 20 |
| TDS Factor Range | Linear (0.01 to 10.00), ISO/EN 27888, 442, NaCl |
| Channels | 2 |
| Accuracy (pH) | ±0.002 pH |
| Range (ISE) | 0.0001 to 19999 |
| Range (Salinity) | 0.010 to 80.00 ppt; 0.01 to 42.00 PSU; or 0.01 to 400.0% NaCl |
| Temperature Compensation | Linear (0.00 to 10.00 %/°C), nLFn (non-linear natural water), nLFu (non-linear ultra-pure water), EP/USP or off |
| Accuracy (Salinity) | ±0.5% reading |
| Resolution (Salinity) | 0.001 ppt minimum; 0.01 PSU minimum; or 0.01% NaCl minimum, auto-ranging |
| Accuracy (Conductivity) | ±0.5% reading |
| Inputs | Channel 1: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference; Channel 2: 8-pin MiniDIN for conductivity with ATC |
| Weight (Metric) | 1.00 kg |
| Resolution (ORP) | 0.1 mV |
| Calibration Points (Conductivity) | 1 to 5 points |
| Resolution (Resistivity) | 0.1 Ω minimum, auto-ranging |
| Isopotential Point | 7.000 pH; 1.000 ion concentration |
| Accuracy (Resistivity) | ±0.5% reading |
| AC Adapter | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Range (TDS) | 0.010 ppm to 500.0 ppt (TDS factor of 1.00); or 0.010 mg/L to 500.0 g/L (TDS factor of 1.00) |
| Resolution (TDS) | 0.001 ppm or mg/L minimum, auto-ranging, up to 4 digits |
| Calibration | pH, ORP, Ion Concentration, Conductivity, TDS, Salinity, Temperature |
| Accuracy (ORP) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Calibration Points | 1 to 5 (pH), 1 (ORP), 1 to 5 (ion), 1 to 5 (conductivity), 1 to 5 (TDS), 1 (salinity), 1 to 2 (temperature) |
| Alarm Output | Calibration reminder alarm, high and low limit alarm per parameter |
| IP Rating | IP54 |
| Weight (English) | 2.20 lbs. |
| Range (Ion) | 0.0001 to 19999 |
| Temperature Range (Metric) | -30.0°C to +130.0°C |
| Temperature Resolution | 0.1°C, 0.1°F |
Eutech Expert pH Pocket Tester
Perform on-the-go, fuss-free measurements for applications such as water treatment, environmental monitoring, education, hydroponics, agriculture, aquaculture, food & beverage and many more!
Thermo Scientific™ Eutech™ ECTestr11+ Multi Range Conductivity Tester
Get quick and accurate conductivity measurements in the field, laboratories, and schools.
Thermo Scientific™ Orion Star™ A325 pH/Conductivity Portable Multiparameter Meter
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Accurately measure pH, conductivity and temperature with our pH/conductivity portable meter for high performance in challenging field tests.
| Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) |
|---|---|
| Range (Resistivity) | 2 ohm to 100.0 meg-ohm |
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
| Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
| Measurement Modes | pH,mV,Relative mV,TDS,ORP with Temperature,Salinity,Conductivity,Resistivity with Temperature |
| Power Supply | 4 AA batteries (included) or universal AC adapter (sold separately) |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Battery Life | 800 hr. |
| Display Type | LCD Graphic, Backlit |
| Resolution (mV) | 0.1mV |
| Data Points | 5000 with Date and Time Stamp |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Warranty | 3 Year Meter |
| Temperature Accuracy | ±0.1°C |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
| Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm |
| Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
| Battery Type | 4 AA (included) |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Dimensions (L x W x H) | 24cm x 10cm x 6.5cm (9.5 in. x 3.9 in. x 2.6 in.) |
| Accuracy (TDS) | 0.5% of reading ±1 digit |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB, RS232 |
| Temperature Range (English) | 22.0°F to 221.0° F |
| Range (Relative mV) | ±2000.0 mV |
| Calibration Points (pH) | 1 to 5 |
| Backlight Option | Yes (Selectable) |
| Range (mV) | ±2000.0 mV |
| Range (ORP) | ±2000.0 mV |
| Methods | 10 per channel with password protection |
| Cell Constant | 0.001 to 199.9cm-1 |
| Temperature (Metric) Reference | 5, 10, 15, 20, 25°C |
| Range (pH) | -2 to 20 |
| TDS Factor Range | Linear (0.02 to 9.99) |
| Channels | 2 |
| Accuracy (pH) | ±0.002 |
| Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
| Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off |
| Accuracy (Salinity) | 0.5% of reading ±1 digit |
| Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
| Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
| Inputs | BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe) |
| Weight (Metric) | 0.5 kg |
| Calibration Points (Conductivity) | Up to 5 |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Resolution (Resistivity) | 1 ohm or 0.1 meg-ohm, auto ranging |
| Isopotential Point | 7.000pH |
| Accuracy (Resistivity) | 0.5% of reading ±1 digit |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003) |
| Range (TDS) | 0.001 ppm to 200.0 ppt |
| Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
| Calibration | pH with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing op |
| Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
| Alarm Output | High/low limit alarm, calibration due alarm |
| IP Rating | IP67 |
| Model | Orion Star A325 pH/mV/RmV/ORP/Conductivity/TDS/Salinity/Resistivity/Temperature Portable Meter |
| Weight (English) | 1.2 lb. |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5.0°C to +105.0°C |
| Temperature Resolution | 0.1°C, 0.1°F |
Thermo Scientific™ Eutech™ SALTTEST11 Salinity Meter
Get quick and accurate salinity measurements in the field, laboratories, and schools.
Thermo Scientific™ Orion™ Versa Star Pro™ Benchtop Meter Without Modules
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
For the ultimate flexibility, combine the Thermo Scientific™ Orion™ Versa Star Pro™ Benchtop Meter Without Modules with up to four measurement modules to build your ideal system.
Thermo Scientific™ Orion™ Versa Star Pro™ pH/ISE Benchtop Multiparameter Meter
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Get premium performance and ultimate flexibility with our benchtop meter with pH/ISE module for pH, ion concentration, and temperature.
| Power Rating | DC input: 9VDC, 1A |
|---|---|
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
| Advanced ISE Functions | Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit |
| Languages | English, Spanish, French, Italian, German, Chinese, Portuguese and Korean |
| Measurement Modes | pH,mV,Relative mV,ORP,Ion Concentration (ISE) with Temperature |
| Range (pH) | -2 to 20 |
| Resolution (ISE) | 0.0001 minimum, 1 to 4 significant digits (user selectable) |
| Channels | 4 (Customizable with modules) |
| Accuracy (pH) | ±0.002 |
| Range (ISE) | 0.0001 to 19990 with selectable units of ppm, Molar, mg/L, %, ppb or none |
| Power Supply | Universal AC adapter (included) |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Display Type | Color graphic LCD with user-customizable options |
| Resolution (mV) | 0.1mV |
| Data Points | 2000 with Date and Time Stamp |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Weight (Metric) | 1.2 kg, modules add 0.2 kg each |
| Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Warranty | 3 year meter and module warranty |
| Temperature Accuracy | ±0.1°C |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Calibration Points (ISE) | 1 to 6 |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Isopotential Point | 7.000pH (adjustable), 1.000 ISE (adjustable) |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR) |
| Log Function Type | Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with |
| Calibration | pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
| Alarm Output | Set point alarm, high/low limit alarm, calibration due alarm |
| Dimensions (L x W x H) | 28cm x 24cm x 10cm (11 in. x 9.5 in. x 3.9 in.), modules add ≤ 2cm (0.8 in.) L & H |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| IP Rating | IP54 |
| Keypad | Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB (2), RS232 |
| Temperature Range (English) | 22.0°F to 221.0° F |
| Range (Relative mV) | ±2000.0 mV |
| Calibration Points (pH) | 1 to 6 |
| Backlight Option | Yes |
| Weight (English) | 2.5 lb., modules add 0.5 lb. each |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5.0°C to +105.0°C |
| Range (mV) | ±2000.0 mV |
| Range (ORP) | ±2000.0 mV |
| Methods | 10 per channel |
| Temperature Resolution | 0.1°C, 0.1°F |
Thermo Scientific™ Eutech™ CyberScan CD 650
CyberScan CD650 allows the simultaneous measurement and display of conductivity and dissolved oxygen.
Thermo Scientific™ Eutech™ PC 450 Multi-parameter Meter Kit
Measure multiple parameters in a cost-effective and convenient way by using only one Eutech™ multi-parameter meter.
| Memory | Stores up to 500 data sets |
|---|---|
| Measurement Modes | pH,ORP,Ion,Conductivity,TDS,Salinity,Resistivity |
| Range (pH) | -2 to 16 |
| Accuracy (pH) | ±0.01 |
| Power Supply | Two AA batteries (included), >100 hours (without backlight); AC adapter (optional) |
| Display Type | LCD Graphic, Backlit |
| Compensation | Temperature: Automatic or manual from -10 to 110 °C |
| Accuracy (Conductivity) | ± 1% full scale |
| Resolution (mV) | 0.1 mV ±999.9 mV; 1 mV beyond |
| Weight (Metric) | Meter: 0.5 kg |
| Calibration Points (Conductivity) | Auto/manual; one point per range |
| Accuracy (mV) | ±0.2 mV +2 LSD or +0.5 % of reading; whichever is greater |
| Temperature Accuracy | ±0.5°C, ±0.9°F |
| Resolution (Conductivity) | 0.01 μS to 0.1 mS |
| Range (Conductivity) | 0 to 200 mS, 0 to 20 mS if using COMBI03BW probe |
| AC Adapter | Optional universal power adapter |
| Range (TDS) | 0 to 200 ppt (TDS factor 1.0) |
| Resolution (TDS) | 0.01 ppm to 0.1 ppt |
| Alarm Output | Calibration due alarm |
| Dimensions (L x W x H) | Meter: 7 7/8in x 3 1/8in x 2 1/4in (20 x 8.3 x 5.7 cm) |
| Accuracy (TDS) | ± 1% full scale |
| IP Rating | IP67 |
| Outputs | USB or RS232 |
| Temperature Range (English) | 14.0°F to 230.0°F |
| Calibration Points (pH) | Up to 6 points: USA, NIST, DIN or custom |
| Weight (English) | Meter: 1 lb |
| Temperature Range (Metric) | -10.0°C to +110.0°C |
| Range (mV) | ±2000 mV |
| Temperature Resolution | 0.1 °C/°F |
Fisherbrand™ accumet™ AP125 Portable pH/Ion/mV/Temperature Meter
Accurate measurements any time, anywhere
| Accuracy (mV) | 0 to ±2000mV |
|---|---|
| Warranty | 3 Years |
| Measurement Modes | pH,Ion,mV,Temperature |
| Range (pH) | 2 to 20 |
| Range | -2 to +20pH |
| For Use With (Application) | pH, Ion concentration, mV, Temperature |
| Includes | Meter, 9V battery, manual |
| Calibration Points | 10 |
| Accuracy | Multiple |
| Display Type | LCD |
| Product Type | Meter Only |
| IP Rating | IP67 |
| Temperature Range (English) | 23°F to 212°F |
| Data Points | 200 |
| Temperature Range (Metric) | -5°C to +100°C |
| Range (mV) | 0 to ±2000 mV |
| Resolution | Multiple |
| Accuracy (ISE) | 0.5% full scale (monovalent ion), 1% full scale (divalent ion) |
|---|---|
| Temperature Accuracy | ±0.3°C, ±0.5°F |
| Calibration Points (ISE) | 2 to 8 |
| Measurement Modes | pH,Ion,Redox |
| Range (pH) | -2 to 20 |
| Range (Concentration) | 0.001 to 19999 ppm (±2000 mV) |
| Accuracy (ORP) | ±0.2 mV |
| Resolution (ISE) | 2 or 3 digits |
| Accuracy (pH) | ±0.002 + 1 LSD |
| Power Supply | 9 V DC adapter, 1.3 A (100/240 VAC, SMPS) |
| Includes | Integral Electrode Holder & 100/240 VAC Adapter and RS232 cable |
| Calibration Points | Up to 6 preset or 5 custom |
| Temperature Compensation | ATC / MTC (0 to 100 °C) (pH only) |
| Outputs | RS232 |
| Temperature Range (English) | 32.0°F to 212.0°F |
| Range (Relative mV) | ±2000.0 mV |
| Calibration Points (pH) | Up to 6 preset or 5 custom |
| Temperature Range (Metric) | 0.0°C to 100.0°C |
| Range (mV) | ±2000.0 mV |
| Range (ORP) | ±2000.0 mV |
| Range (DO) | ±2000.0 mV |
| Temperature Resolution | 0.1 °C / 0.1 °F |
| Resolution (ORP) | 0.1 mV |